CONNECT WIRING
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
INSTALL MASK &
FINISH CEILING
5. Insert mask
and finish
ceiling.
Tape mask into
housing. Mask
protects unit dur-
ing construction.
Remove before
installing grille.
Install ceiling
material. Cut out
around housing.
WIRNG PLATE
& SCREW
SCREW
FROM PARTS
BAG
VENTILATION FAN
INSTALL GRILLE
6. Attach
grille to
housing.
Squeeze grille
springs and
insert them
into tabs on
each side of
housing.
7. Push grille
against
ceiling.
SERVICE PARTS
Key No.
Part No.
1
97020009 Housing
2
97018331 Duct Connector
3
97018721 Parts Bag (includes wiring plate &
4
97018447 Wire Panel/Harness Assembly
5
97020011 Blower Assembly
6
97018532 Grille Assembly (includes key no. 7)
7
99140208 Grille Spring (2 req'd)
8
97018014 Spacer (2 supplied)
9
97020013 Hanger Bar Kit
Order service parts by "Part No." - not by "Key No."
3
8
2
9
5
3
MODEL QTXEN150
Description
all screws)
Replacement parts can
be ordered on our web-
site. Please visit us at
1
www.nutone.com
8
3
9
3
4
7
Page 4
6
99045437A