Cleaning
NOTICE! Risk of product damage! Never
submerge device in water while cleaning.
Do not use cleaning agents or solvents. Wipe the
device using a dry cloth.
Storage and frost potection
The pressure switch and accessories that are not
completely drained can be destroyed by frost. Com-
pletely drain the pressure switch and accessories
and protect them against frost.
Keep this appliance in well-ventilated dry premises
with temperature not going below +5°C.
When not in use, keep this appliance stored in a
safe place out of reach of children.
TROUBLE SHOOTING GUIDE
Problem
Cause
Pump does
No mains supply
not start
Pump not switched
on
LED-failure is on
Not enough pump
pressure
The switch-on pres-
sure is set too low
The dry-run
safety is activated,
because the the
switch-on pressure
is set too high
6
Pump start
and stop
constantly
Pump does
not stop
ENVIRONMENT
Remedy
Check mains supply
Switch on pump
Only for EC countries
Do not dispose of power tools into domestic waste.
According to the European Guideline 2012/19/EC
Press the reset button
for Waste Electrical and Electronic Equipment and its
implementation into national right, power tools that
Check that the pump
are no longer usable must be collected separately
pressure is 0.8bar
and disposed of in an environmentally friendly way.
higher than the
WARRANTY
starting pressure of
the switch
VONROC products are developed to the highest
By turning the pres-
quality standards and are guaranteed free of
sure setting screw
defects in both materials and workmanship for the
clockwise, the switch-
period lawfully stipulated starting from the date of
on pressure will be
original purchase. Should the product develop any
increased
failure during this period due to defective material
and/or workmanship then contact VONROC directly.
By turning the pres-
sure setting screw
The following circumstances are excluded from this
anti-clockwise, the
guarantee:
switch-on pressure
• Repairs and or alterations have been made
will be reduced
• Normal wear and tear;
• The tool has been abused, misused or
• Non-original spare parts have been used.
The switch-on
pressure is set too
high
Output side leaking
Output side leaking
The switch-on
pressure is set too
high
Faulty and/or discarded electrical or
electronic apparatus have to be collected at
the appropriate recycling locations.
or attempted to the machine by unauthorized
service centers;
improperly maintained;
By turning the pres-
sure setting screw
anti-clockwise, the
switch-on pressure
will be reduced
Check the outlet hose
and connections
Check the outlet hose
and connections
By turning the pres-
sure setting screw
anti-clockwise, the
switch-on pressure
will be reduced