INSTALLATION
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
WARNING : To avoid possible personal injury
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
or equipment damage, a register electrician or
an authorized service representative should
perform installation and all service. Under no
circumstances should an unqualified person
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
attempt to wire into utility circuit.
Give the generator at least two feet of space from
any nearby wall to dissipate heat.
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
POWER DERATING FACTOR
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
Altitude
(masl)
15°C
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
(59°F)
300
1.00
500
0.98
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
1000
0.92
1500
0.86
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
2000
0.80
3000
0.69
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
BEFORE OPERATION
GROUNDING THE GENERATOR
1
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
The National Electric Code requires that this product be
properly connected to appropriate earth ground to help
prevent electric shock. A ground terminal connected
to the frame of the generator has been provided for
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
this purpose. Connect a length of a heavy gauge (12
AWG min.) bare cooper cable between the ground lug
attached to the generator´s frame (identified with a label
EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.
with the ground symbol- see figure below) and a cooper
rod drawn 1 meter into the ground which should provide
a suitable ground connection. However, consult with
a local electrician to insure that local codes are being
PROPIEDAD EVANS.COM.MX PROPIEDAD EVANS.COM.MX PROPIE
adhered to.
4
WARNING
Temperature
25°C
40°C
45°C
(77°F)
(104°F)
(113°F)
0.98
0.96
0.95
0.96
0.94
0.93
0.90
0.88
0.87
0.84
0.82
0.81
0.79
0.76
0.75
0.67
0.64
0.64
1
To avoid back feeding into utility systems, isolation
of the residence electrical system is required.
2
Before temporary connection of the generator to
the residence system, turn off the main service
disconnecting device.
3
If your generator is to be used as a stand – by power
source in case of utility power failure, it should be
installed by a registered electrician and in compliance
with all applicable local electrical codes.
4
Proper use requires that a double throw transfer
switch be installed by licensed qualified electrician
so that the building's electrical circuits may be safely
switched between utility power and the generator
output; thereby preventing back feed into the power
utility's electrical system.
5
Always follow local codes and regulations that apply
to the installation of any item that concerns this
product.
1. NFPA 70 – National Electrical Code.
2. NFPA 37 – Standard for Installation and Use of
Stationary Combustible Engines.
3. Agricultural Wiring handbook of Farm Standby
Electric Power.
Before making permanent connections a double throw
transfer switch must be installed. To avoid electrocution
or property damage, only a trained electrician should
connect generator to residence electrical system.
California law requires isolation of the residence
electrical system before connecting generator to
residence electrical system.
50°C
55°C
(122°F)
(131°F)
0.94
0.93
0.92
0.91
0.86
0.85
0.80
0.79
0.74
0.74
0.63
0.62
WARNING
WARNING : To avoid back feeding into
utility system, isolation of the residence
electrical system is required. Before temporary
connection of a generator to the residence
electrical system turn off the main switch.
Generator Ground Terminal
Connect a bare # 12 AWG copper
cable from the ground terminal to
an earth grounding point
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE