Ensamblaje
7. Realice la prueba de fuga
ADVERTENCIA
Realice todas las pruebas al aire libre.
Apague todas las llamas expuestas.
NUNCA haga la prueba contra fugas mientras esté fumando.
No use la fogata a gas hasta que todas las conexiones hayan
sido probadas contra fugas y no haya una fuga.
(I) Make 2-3 oz. of leak test solution (one part liquid dishwashing
detergent and three parts water).
(III) Apply several drops of solution whe re hose attaches to regulator.
(IV) Apply several d rops of solution whe re regulator connects to cylinder.
(V) Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
(I) Turn cylinder valve OFF.
(II) If leak is at hose/regulator connection: tighten connection and
perform another leak test. If bubbles continue appearing, the hose
should be returned to the place of pu rchase.
(III) If leak is at regulator/cylinder valve connection: disconnect,
reconnect, and perform another leak test. If you continue to see bubbles
after several attempts, cylinder valve is defective and should be returned
to cylinder place of pu rchase.
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, you must
perform a complete leak test.
• No almacene un tanque de repuesto de gas de PL debajo o
cerca de este aparato.
• Nunca llene el tanque más allá del ochenta por ciento (80%).
• Coloque la tapa anti-polvo en la salida de la válvula del tanque
siempre que no esté usando el tanque. Instale en la válvula del
tanque solamente el tipo de tapa anti-polvo que es suministrada
con la válvula del tanque. Otro tipo de tapas o tapones pueden
resultar en fuga del gas propano.
PRECAUCIÓN
¡No utilice esta mesa con fogata a gas si el recipiente
Página 10
7
Conexión de la manguera y del regulador
Conexión del regulador/cilindro