Technical specifications
1. Safety precautions
The
flexible
current
sensor
designed and tested to comply with the
safety standard, IEC 61010-1:2001/
The flexible current sensor has been designed
and tested to comply with EN61010-1 and
61010-2-32:2002. Before using the flexible
current sensor for the first time, carefully
read the following:
1. Smilics Technologies may not be
held liable for any personal injuries
that could be derived from improper
installation or use of the equipment.
2. The use of the probe on non-insulated
conductors is limited to 600 VAC
RMS or DC at frequencies below 1 kHz.
3. Do not expose the probe to
aggressive or explosive environments.
4. Do not use the probe if you have any
reason to believe that it is not
has
been
functioning correctly or that it is
defective.
5. For measurements on non-insulated
conductors, use the appropriate and
necessary personal protective
equipment.
2. External connections
1. It requires a 95 V and 400 VAC
power supply.
2. It requires access to Internet through
a wireless network.
Requirements of the system administrator
It is necessary to open the following ports:
- Port 8080 for Http Get/Post
- Port 53 for DNS
- Port 80 for Internet
Remove filters from MACs, firewalls or
similar that may prevent your computer from
connecting to the Internet.
This equipment is not suitable for enterprise
or radius systems.
Use of the Wibeee Max
Be sure to correctly make the connection of
the voltage and current sensors in order to
obtain the correct measurement.
Follow the correct order: N, L1, L2 and L3 for
voltage and L1, L2 and L3 for current.
Verify that the clamps measure correctly
once the equipment is installed.
If there is any incident, it is recommended to
disconnect the clamps from the equipment,
wait 10 seconds and reconnect so that they
start correctly.