Specifications; Maintenance - DeWalt DXH330 Manual De Instrucciones

Calentador eléctrico de aire forzado
Ocultar thumbs Ver también para DXH330:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Starting Instructions, After Heater
Has Been Professionally Wired
1. Place the heater on a stable and level surface. Insure clearance to
combustibles are observed (see table on this page).
2. Turn thermostat counter-clockwise to lowest setting.
3. Depress power switch into the on "I" position.
4. Turn thermostat knob up (clockwise) until desired temperature is reached. The
heat "on" indicator light will illuminate when the knob reaches a temperature
higher than that of the current room.
5. The heating element and fan will remain on until the temperature
setting is reached. The heating element will cycle on and off as needed. The fan will
remain on as long as the control switch is in the on position.
DXH1000TS ONLY: The DXH1000TS is equipped with 10kW/7kW power selection
switch, located on the back of the heater in the lower right corner. The low
(7kW) setting requires a power source of 240Vac/28A on a 30 amp/2
pole circuit breaker. The high (10kW) setting requires a power source
of 240Vac/42A on a 50 amp/2 pole circuit breaker. Always confirm your power
source and power selection switch setting prior to operating the heater.
To Stop Heating
1. Rotate the thermostat knob to the lowest position.
1a. Let cool for 10 minutes.
2. Flip the power switch into the off "O" position.
NOTE: This heater is equipped with an overheat limit switch which may cause
the heater to stop. If the power switch is in the on "I" position and the heat
indicator light and fan are both off, the overheat limit switch has activated. Check
and remove the cause of the overheating before restarting. This can take up to
15 minutes to cool before it can be restarted.

Maintenance

WARNING:
Never attempt to service the heater while the unit is hot, In use, or plugged in. Only
qualified service technicians should service these units.
• Thoroughly inspect the unit prior to use.
• Keep heater clean and free of dust and debris.
• The use of an air compressor can be used to blow out the dust from the heater case.
Be sure to only use moderate air pressure as to not damage any internal components.
• A soft dry cloth should be used for cleaning of outer shell and handle.
• The fan motor is sealed and does not need to be lubricated.

Specifications

Model:
DXH330
Heat Output BTU/WATTS
11260/3300
Airflow (CFM)
200
Electrical Supply
240Vac
Thermostat
23°F - 95°F
Power Cord
Min. 14/3 AWG for 10' or Less
Dimensions: (L"xW"xH")
14"x12"x15"
Weight (lbs.)
19 lb.
Clearance to Combustibles
Outlet (Feet)
6 (1.8m)
Rear (Feet)
2 (.6m)
Tom (Feet)
2 (.6m)
Bottom
Non-combustible floor
ON/OFF
HEAT ON INDICATOR LIGHT THERMOSTAT
4
DXH1000TS
22861/6.7kW-4121/10kW
325
240Vac
23°F - 95°F
Min. 10/3 AWG for 10' or Less
23"x13"x16"
37 lb.
FIG. 1