4. Installation
Refer to the illustration on page 2 of this manual.
•
Choose a proper location for the sensor. Avoid places where temperature
changes frequently, e.g. near air conditioners or heating devices. Also avoid
moving obstructions or objects in the detection field of the sensor to prevent
unnecessary activation. Max. installation height is 3.5m. Note: the detector
needs ±30s to initialize when power is connected.
•
Set the light sensitivity (LUX) and ON‐timer (TIME) to the desired values.
Use a small screwdriver for this.
5. Technical Specification
detection angle
distance
motion speed 0.6~1.5m/s
ON‐timer
light sensitivity
rated load
power supply
power consumption
installation height
dimensions
weight
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of
this device. For more info concerning this product and the latest version of
this user manual, please visit our website www.velleman.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved.
No part of this manual or may be copied, reproduced, translated or reduced to any
electronic medium or otherwise without the prior written consent of the copyright
holder.
19.10.2010
PIR451
360°
up to max. 6m (<24°C)
adjustable from 10s (±3s) up to 7min. (±2min.)
3‐2000 Lx (adjustable)
40W (incandescent lamps) / 20W (energy saving
lamps)
230Vac/50Hz
0.45W (active) / 0.1W (stand‐by)
2.0~3.5m
Ø50 x 130mm
±100g
4
Rev. 02
©Velleman nv