Descargar Imprimir esta página

Uline H-7127 Manual De Instrucciones página 2

Ocultar thumbs Ver también para H-7127:

Publicidad

Idiomas disponibles

Idiomas disponibles

UNPACKING
The unit is shipped completely assembled and sitting on
a plastic pallet with a large cover box strapped over the
unit. Cut the straps and remove the box by lifting it over
the unit. Remove pallet and place cooler on a level
surface.
CONNECTING THE WATER AND
ELECTRICITY
WATER CONNECTION
NOTE: Unit must be in upright and level position.
After the unit has been thoroughly tested at the factory,
a special two-sided brass hose adapter is attached to
the water inlet on the side of the unit, which is below
the spray bar adjustment and drain valves. A standard
garden hose is attached to this brass hose adapter and
cinched down to preclude leaks. Visually verify that the
hose washer is in position and in good condition.
NOTE: Water supply inlet pressure should be
limited to 50 psi maximum.
Once the hose connection is made, water may be
turned on to the unit. Water should now be entering
through the float valve to fill the sump tank. To verify that
connections are secure, visually inspect connections for
leaks. Remove the cooling pads. See page 7 for details.
These coolers utilize a GFCI (Grounded Fault Circuit
Interrupter) or ELCI (Equipment Leakage Circuit
Interrupter) to help protect users against ground
electrical faults, which prevent some fire and electrical
shock hazards. These devices are intended to trip at
very low leakage currents.
• H-7127, H-8657, and H-9928 use a GFCI, which is built
into the power cord.
LIQUID LEVEL INDICATOR / PUMP SHUTOFF
A liquid level indicator with integral shutoff gives a visual
indication of the water level in the evaporative cooler
and will shut off the pump once the water reaches a
certain threshold. When this occurs, a red light on the
PAGE 2 OF 21
SETUP
Once the sump tank is filled, the water flow should stop
and the inlet connections may now be visually checked
for leaks. Pay particular attention to the hose connection
into the float valve and the connections into the brass
inlet fitting.
All of these inspections have been performed at the
factory but shipping may have caused connections
to loosen.
The cooling pads may now be replaced. See page 7
for details.
ELECTRICAL CONNECTION
This unit utilizes a single power cord and control switches.
Before connecting the plug to an outlet, ensure that
there is no standing water where the cord may lie or the
operator is standing. The use of separate multiple outlet
devices are not recommended.
When making electrical connections, ensure that local
and national codes are adhered to. Use only with GFCI
protected receptacles.
Please refer to the barcode product label on the side of
the unit for specific electrical requirements.
GFCI/ELCI
• H-7128 uses an ELCI, which is built into the power
• The GFCI on H-7127, H-8657, and H-9928 will
LIQUID LEVEL INDICATOR
control panel will illuminate to draw attention to the low
water level condition and alert the user that the pump
has shut off. This light may cycle on and off for a few
minutes to draw attention to the low water condition as it
tries to exhaust the remaining water.
NOTE: Unit must be in upright position with
cooling pads installed!
NOTE: H-7128 must be used with a 5-20R outlet.
cord and requires a 5-20R (120V) electrical outlet.
automatically reset when the evaporative cooler is
plugged into an electrical outlet. The ELCI on H-7128
will not automatically reset when the evaporative
cooler is plugged into an electrical outlet; the reset
button located on the ELCI device must be pressed
each time the evaporative cooler is plugged in.
0722 IH-7127

Publicidad

loading

Este manual también es adecuado para:

H-7128H-8657H-9928