MODEL
AU-A1ZBDSS
DESCRIPTION
2 GANG SWITCHED SOCKET
VOLTAGE (V)
230V AC
HERTZ (HZ)
50Hz
PRODUCT RATING
0.08-13A
RESISTIVE LOAD
3000W
INDUCTIVE LOAD
3000VA
RF FREQUENCY
2.4GHz, IEEE 802.15.4
WORKING ENVIRONMENT TEMP
0°C to 40°C
WORKING ENVIRONMENT HUMIDITY
≤85% Non Condensing
ENERGY MONITORING ACCURACY
Typ +/- 3.0%
PROTOCOL
Zigbee HA1.2
FREQUENCY BAND
2.40-2.483Ghz
DISTANCE
30m (open field)
• This socket shall be protected by a 32A MCB.
• For support please call the technical helpline - 01707 351 859
• Installation must be carried out in accordance with the latest edition of the
Wiring Regulations by a qualified electrician.
• Hereby, Aurora Limited declares that the radio equipment type
AU-A1ZBDSS is in compliance with Directive 2014/53/EU. The full text of the
EU declaration of conformity is available at the following internet address:
www.auroralighting.com/ProductDetail/AU-A1ZBDSS
USING THE APP TO PAIR THE DOUBLE SOCKET WITH
YOUR PHONE
1. Download AOne UK App from your App Store
2. Follow instructions on the App to pair the double socket.
General Functions:
On initial power up the units will automatically go into pairing mode for 3
minutes which will appear as a fast blue flash.
This can be disabled at any time by pressing either power button to switch
the sockets manually for non smart control.
The LED ring around the button will light up Blue when the socket is ON.
The LED ring around the button will light up Red when the socket is OFF.
(The LED ring can be disabled for the OFF state through the AOne UK App)
REMOVE EXISTING 2 GANG SWITCHED SOCKET
1
2
This socket shall be
protected by a 32A MCB
WIRE AND INSTALL THE AONE ZIGBEE DOUBLE SOCKET
6
Important information: The fixing screws are not earthed, please ensure that this socket is wired correctly.
Connect to earth terminal in the back box
Current UK wiring colours are as follows:
Green/Yellow = Earth
Brown = Live
Blue = Neutral
8
When moving socket into the backbox ensure that none of the
cables are trapped or damaged.
Suitable for 35mm back box
10mm Spacer included for 25mm back box
8A
8B
www.auroralighting.com
3
7
Important information: If the back box has
an earth terminal please add a piece of
earth cable from one of the socket earth
terminals to this terminal.
9
Screws and caps included on inside
of front plate.
Ensure screws are fully tightened.
Leave existing wiring
4
Ensure backbox
has a minimum
depth of 25mm
10
Document Version: AU-A1ZBDSS_V1_19