Descargar Imprimir esta página

ELEMENTI OFG410NG Manual Del Propietário página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

GAS COMPONENT CONNECTION CHECKS
2. Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris between the igniter
pin, thermocouple and the burner tube.
CORRECT
3. Make sure that the igniter pin and thermocouple are correctly positioned.
- The igniter pin should be pointed straight to the thermocouple.
- The thermocouple should be positioned 5mm / 0.196" away from the burner tube.
Thermocouple
Wire
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
Thermocouple
Valve
Igniter Box
Burner pots
5mm /
0.196"
Igniter Pin
16 / 60
INCORRECT
Thermocouple Wire
Wire should
be in line
with valve
Valve

Publicidad