7.    W hen you charge a new battery pack or a battery pack which has not been used for a long 
period, it may not accept a full charge. This is a normal condition and does not indicate a
problem. You can recharge the battery pack fully after discharging it completely a couple of
times.
8.    U nplug the charger from the power source after finish the charge.
9. Please remove the battery from the unplugged charger for storage.
The LED Light on the Charger
Power On (Green light flashes slowly)
Battery Low (Red light stays illuminated)
Battery charged 80% (Green light flashes rapidly)
Battery charged 100% (Green light stays illuminated)
Battery Pack temperature is too hot or too cold (Red light flashes slowly)
Battery Pack malfunction (Red and Green lights stay illuminated)
Battery Pack LED Indication Function (Optional)
The Battery Pack has a "SW" button and 4-step green LEDs for indicating remaining capacity 
status. The fuel gauge green LED will indicate when the "SW" button is momentarily pressed.
Remaining Capacity LED Indication
LED 1 (green)
LED 1, 2 (green)
LED 1, 2, 3 (green)
LED 1, 2, 3, 4 (green)
WARNING
1.    C harger is plugged into a 100-240V a.c outlet only.
2. If the battery pack is too hot or too cold, the charger will not fast charge the battery pack
and the red Indicator light is "blinking". When the battery pack temperature returns to 
between 0°C (32°F) and 50°C (122°F), The charger will automatically begin charging.
3. If both red and green indicator lights are "ON" the battery pack either does not comply or is
defective. Please contact your retailer.
4. Do not charge the battery pack in the rain, snow or high temperature environment.
5.    D o not charge battery pack when environment temperature is below 0°C (32°F) or above 
40°C (104°F)
6.    W hile charge the cool battery pack (below 0°C) in the warm indoor, keep the battery pack in 
the room for one hour to warm up before starting the battery pack.
7.    R emove the plug after finishing the charge.
8. The charger should be cooled at least one hour after continue charging three times.
9. Do not use generator for charging the battery pack.
RC Status
0% - 25%
26% - 50%
51% - 75%
76% - 100%
8