Maintenance
This Tester is designed to provide years of dependable service,
if the following care instructions are performed:
1. KEEP THE TESTER DRY. If it gets wet, wipe it off.
2. USE AND STORE THE TESTER IN NORMAL TEMPERATURES. Temperature
extremes can shorten the life of the electronic parts and distort or melt
plastic parts.
3. HANDLE THE TESTER GENTLY AND CAREFULLY. Dropping it can damage the
electronic parts or the case.
4. KEEP THE TESTER CLEAN. Wipe the case occasionally with a damp cloth.
DO NOT use chemicals, cleaning solvents, or detergents.
5. USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE.
Remove old or weak batteries so they do not leak and damage the unit.
6. IF THE TESTER IS TO BE STORED FOR A LONG PERIOD OF TIME, the batteries
should be removed to prevent damage to the unit.
Tester Description
1. Test Probe (–) L1
2. Test Probe (+) L2
3. Flashlight
4. LED voltage level indicators
5. LED for single-pole test
6. LED for hazardous voltage warning
7. LED for Right rotary field indication
8. LED for Left rotary field indication
9. LED for continuity
10. Self-test switch (AUTO TEST)
11. Flashlight on button
12. Battery case
13. LED for +DC polarity
14. LED for -DC polarity
(NOTE: 13. LED and 14. LED illuminate
for AC voltage indication)
1.
2.
Indicators/Warnings
3.
14.
13.
12.
Operation
Function Test/Self-Test
WARNING:
voltage source before performing the self-check test function.
Press the "AUTO TEST" button. The beeper will sound and the continuity LED
and all 8 voltage LEDs will illuminate. Replace the batteries immediately if the
tester is not functioning correctly.
AC/DC Voltage Measurements
WARNING:
precautions when working on live voltages.
1. Touch the test probes across the
circuit being measured.
4.
2. The tester will turn on automatically
if the voltage exceeds 6 volts.
5.
3. The LEDs will indicate the voltage.
4. For AC voltage, the "+" and "-"
6.
polarity LEDs will illuminate.
7.
5. For DC voltage, the "+" polarity
8.
LED will illuminate if the "L2" test
9.
probe is touching the positive side
of the circuit. The "-" polarity LED
10.
will illuminate if the "L2" test probe
is touching the negative
side of the circuit.
11.
NOTE: The " " hazardous voltage warning LED will illuminate if the voltage
exceeds 50 volts even if the batteries are low or have been removed.
3
To avoid electric shock, disconnect the test leads from any
Observe all safety
Indicators/Warnings
4
120VAC