Rev 09 11-01-2021
Figure 5: Second Smart BatteryProtect in between a battery charger or MPPT solar charge controller
and a Li-ion battery
(applicable with VE.Bus BMS or smallBMS)
The second SBP replaces a Cyrix-Li-charge relay (advantages: lower power consumption, alarm relay).
(not applicable if the charger has remote on-of f contacts and can be controlled with an interf ace cable between the BMS and the charger)
Choose program
f or this application.
Caution: uncontrolled reverse current will f low through a Smart BatteryProtect if Vout > Vin. Theref ore, never use a Smart BatteryProtect f or
battery to battery charging.
Figure 6: Application example for a vehicle or boat, with on/off switch between H and L
(applicable with VE.Bus BMS or smallBMS)
Victron Energy B.V. / De Paal 35 / 1351 JG ALMERE / Nederland
Telefoon: (+31) (0)36 535 97 00 /
www.victronenergy.com
/ e-mail: sales@victronenergy.com