Descargar Imprimir esta página

KROHNE OPTISOUND 3030 C Manual página 49

Ocultar thumbs Ver también para OPTISOUND 3030 C:

Publicidad

– Update, create new or delete the empty vessel curve
sound_velocity
– Set up to suit the process conditions
sound_velocity_unit
– Unit code of 'Sound_velocity'
Temperature
– Process temperature. Selected as input to AIFB by setting 'Channel' = 4. Unit derives from
'Temperature.unit'
temperature_unit
– Unit code of 'Temperature', 'Max./Min._peak_temperature_value'
max_peak_temperature_value
– Holds the maximum process temperature. Write access resets to current value. Unit derives
from 'Temperature.unit'
min_peak_temperature_value
– Holds the minimum process temperature. Write access resets to current value. Unit derives
from 'Temperature.unit'
9.3
Dimensiones
Carcasa
~ 69mm
(2
23
/
")
32
ø 77mm
(3
1
/
")
32
M20x1,5/
½ NPT
1
Fig. 29: Variante de carcasa en grado de protección IP66/IP67 e IP66/IP68; 0,2 bar (con módulo de visualización y
configuración aumenta la altura y el ancho de la carcasa en 9 mm/0.35 in)
1
Carcasa plástica
2
Carcasa de acero inoxidable
3
Carcasa de aluminio de dos cámaras
4
Carcasa de aluminio
OPTISOUND 3030 C • Foundation Fieldbus
~ 69mm
(2
23
/
")
32
ø 77mm
(3
1
/
")
32
M20x1,5/
½ NPT
2
~ 87mm (3
27
/
")
64
ø 84mm
(3
5
/
")
16
M20x1,5/
3
½ NPT
~ 116mm
(4
9
/
")
16
ø 84mm
(3
5
/
")
16
M20x1,5/
M20x1,5
½ NPT
4
9 Anexo
49

Publicidad

loading