Céliane™
Dimmer switch with indicator 300W TC
672 12
Technical data
Min.
20 W
20 W
110 V
Max.
150 W
150 W
Min.
20 W
20 W
230 V
Max.
300 W
300 W
Incandescent lamp
Halogen lamp
halogen lamp with ferromagnetic or electronic
transformer
Cabling
Important :
- Ferromagnetic transformers must be charged to more than
60% of their rated power.
- Allow for the efficiency of ferromagnetic transformers when
calculating the permissible power (e.g. transformer for a
50-W lamp with 0.78 efficiency => actual power consumed
by the transformer = 64 VA).
Safety instructions :
This product should be installed preferably by a qualified electrician. Incorrect installation and use can entail risk of
electric shock or fire. Before carrying out the installation, read the instructions and take account of the product's specific
mounting location.
Do not open up the device. All Legrand products must be exclusively opened and repaired by personnel trained and
approved by LEGRAND. Any unauthorised opening or repair completely cancels all liabilities and the rights to replacement
and guarantees.
Only use genuine accessories.
Voltage
Frequency
20 VA
150 VA
20 VA
300 VA
Electronic protection :
- In case of overload and above the maximum use temperature, the product
automatically regulates the power with reduced lighting.
- In case of short-circuit or high overload, the dimmer switch goes off. After
fault clearance, the product is again operational
13
N
L
14
100 - 240 V~
50 - 60 Hz
2 x 1.5 mm
2
or 1 x 2.5 mm
2
Depth = 40 mm min.
EN 50065 - IEC 60669-2-1
- 5°C to + 45°C