Descargar Imprimir esta página

HAMPTON BAY HB-4133-OR Guía De Uso Y Cuidado página 9

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation (continued)
3
Adjusting the SENSITIVITY
switch
To increase the detection zone, slide the
"SENSITIVITY" switch toward the "HI" position.
To decrease the detection zone, slide the
"SENSITIVITY" switch toward the "LO" position.
NOTE: The motion sensor is more sensitive to motion
moving across the front of the sensor. The motion sensor
is less sensitive to motion moving directly toward the front
of the sensor.
NOTE: The higher the "SENSITIVITY" setting, the greater
the possibility of false triggering. To reduce false triggering,
slide the "SENSITIVITY" switch toward the "LO" setting.
A
TEST 1 5 10 MIN
ON-TIME
5
Adjusting the motion sensor
coverage area
NOTE: Grasp the sensor only as shown and turn the
entire sensor. Any other method may damage the sensor.
DO NOT force it past the stops.
Move the sensor (B) head left or right to
change the coverage area.
B
Rotating the sensor head to change the
coverage area
4
LO - M - HI
SENSITIVITY
6
A
9
Please contact 1-855-HD-HAMPTON for further assistance.
Adjusting the ON-TIME switch
NOTE: The "ON-TIME" switch determines the amount of
time the light will stay on full bright after all motion has
stopped.
Set the "ON-TIME" switch to the 1, 5, or 10
minute position.
A
TEST 1 5 10 MIN
ON-TIME
Using manual mode
NOTE: Manual mode overrides the motion sensor and
"ON-TIME" control so the light will operate full bright. This
feature only works at night and only for one night at a time.
The motion sensor will reset to motion sensing mode after
6 hours or sunrise, whichever comes first. Manual mode
can be toggled on and off using a wall switch.
To turn manual mode on, switch the light off
at the wall switch for 1 to 3 seconds and then
back on.
To turn manual mode off, switch the light off
at the wall switch for 1 to 3 seconds and then
back on.
NOTE: If the power to the light fixture is off for more than
5 seconds, allow the motion sensor to warm up prior to
switching to manual mode.
Turn the switch OFF
for 1 to 3 seconds
LO - M - HI
SENSITIVITY
Turn the switch
back ON
HAMPTONBAY.COM

Publicidad

loading

Este manual también es adecuado para:

440186