Remove the lid from the control
module.
Connect the light switch to
connection a.
Secure the cable with the strain relief
provided.
Close and screw on the lid of the
control module.
If earthing cannot be ensured using
the fixing screws, connect the
earthing wire provided.
en - Operating and installation instructions
After all components have been
installed, carry out an electrical
safety check in accordance with
local regulations (e.g. VDE 0701-1 in
Germany).
Connecting the potential-free
contact
The potential-free connection can be
used to control other appliances
depending on the switch status of the
cooker hood fan.
When connecting ventilation
appliances, the advice of a building
regulations inspector must be
sought.
The contact does not supply a defined
voltage (potential-free). This means that
the connection is suitable for universal
application. The maximum switching
capacity of the contact is 230 V/2 (1) A.
The contact closes when the On/Off
button for the cooker hood is switched
on. The indicator light for the On/Off
button and the indicator light for the
second fan setting will come on.
Remove the lid from the control
module.
13