Descargar Imprimir esta página

TECHCON SYSTEMS TS200 Guia Del Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

8
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
LCD does not
No power input
light
System will not
Foot switch not
actuate
plugged in or
improperly plugged
in
Defective foot
switch
Broken wire or loose
connection inside
unit
Defective solenoid
Defective PC board
System will not
Insufficient air
pressurize
pressure
Air hoses not
plugged in
Regulator defective
System will not
Vacuum setting is
pull vacuum
too low
Defective solenoid
Defective vacuum
venturi
Defective vacuum
needle valve
Inconsistent
Air bubbles in
dispensing
adhesive
Dispense time is too
low
Dispense needle
started to clog
All manuals and user guides at all-guides.com
CORRECTION
Check power cord
connections
Turn on power
Check foot switch
connection
Foot switch needs to be
repaired or replaced
Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
Replace solenoid
Replace PC board
Increase air supply
pressure
Check connection
Replace regulator
Increase vacuum setting
Replace solenoid valve
Replace venture
Replace needle valve
Reduce vacuum setting
Increase dispensing time
Replace needle
7
9
MAINTENANCE
The dispenser is designed and built to be relatively maintenance free. To assure
trouble free operation, the following recommendations should be followed:
1.
Make certain air supply is clean and dry.
2.
Avoid turning barrels upside down or laying barrel so that material may
run through air line to internal components.
3.
Avoid connecting the unit to excessive moisture or solvent saturation.
4.
Avoid connecting air supply exceeding 100 psi (6.9 bars) for the TS200
and 15 psi (1.03 bars) for the TS215.
5.
Use only Amyl Alcohol to clean outside surface of the main housing.
6.
Use only soft cloth to clean the LCD.
10 SPARE PARTS AND ACCESSORIES
For TS200/215 spare parts and accessories information, please visit the TS200/215
User Guide webpage at http://www.okinternational.com
11 LIMITED WARRANTY
OK International warrants this product to the original purchaser for a period of one
(1) year from date of purchase to be free from material and workmanship defects but
not normal wear-and-tear, abuse and faulty installation. Defective product or
subassembly and components under warranty will be repaired or replaced (at OK
International's option) free of charge. Customer with defective product under
warranty must contact the nearest OK International office or distributor to secure a
return authorization prior to shipping the product to the assigned OK International
authorized service center. For nearest OK International office or distributor contact
information, please visit www.okinternational.com. OK International reserves the
right to make engineering product changes without notice.
12 I/O CONFIGURATION AND END OF CYCLE SWITCH
For TS200/215 I/O Configuration and End of Cycle Switch information, please visit
the TS200/215 User Guide webpage at http://www.okinternational.com