UK
Troubleshooting
If your Drinks Dispenser develops a fault, please check the following points before making a call to the
Helpline.
Fault
The appliance is
not working
The dispenser is
not cooling
The mixing paddles
are not working
The tank is leaking
Technical Specifications
Model
Voltage
CF760 230V 50Hz
CF761 230V 50Hz
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 3 amp fuse as standard.
The plug must be connected to a suitable mains socket.
This appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
5
Probable Cause
The appliance is not
switched on
Plug and lead are damaged Call POLAR agent or qualified technician
Fuse in the plug has blown Replace the plug fuse
Power supply
Internal wiring fault
Coolant leak
Fan motor failed
Airflow obstructed to the
condenser
Condenser is clogged
Mixing motor has failed
Gasket problem
Power
Current Tanks
268W
1.2A
291W
1.6A
Check the appliance is plugged in correctly and
switched on
Check power supply
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Call POLAR agent or qualified technician
Increase the gap between appliance and obstacles/
heat source
Remove side panels and clean condenser
Call POLAR agent or qualified technician
Check the gaskets and replace if necessary
Capacity
Refrigerant
(litres)
1
12
R134a 90g
2
24
R134a 120g 635 x 420 x 450
Action
Dimensions
L x W x H mm
635 x 220 x 450
Weight
(kg)
19