3.7
bLOC (Modify/delete blocks)
It is possible to modify the time and temperature of
each phase and even delete phases.
First, refer to the table of Standardised Programmes
to confirm which blocks are in the programme you wish
to modify.
Next, enter this block and modify the parameters as
follows:
1- When bLOC is displayed on the screen,
press Start.
2-
B 1 is displayed, press the INC and DEC
( , ) keys to go to the block you wish to
modify. Press Start.
3-
"tIME" is displayed on the screen, press
the INC or DEC ( , ) keys to go to "tEMP"
(temperature). To modify the time, press
Start when "tIME" is displayed and the
default time setting will be shown. Use the
INC and DEC ( , ) keys to modify this
value and press Start to confirm. Press
Express to exit.
4- To modify the temperature, go to "tEmP",
press Start and the default temperature
setting is displayed, modify the value using
the INC and DEC ( , ) keys and press
Start to exit.
5-
If the time is set to 0 seconds, the block is
cancelled and will not run, i.e. the next
phase will be run. It is not possible to
cancel the last spin of each programme
and therefore this is limited to a time of
one minute.
6-
Warning! Please note that some blocks
are used in more than one programme at a
time and, if these block are changed, all
the programmes in which they are used
will be changed.
3.8
Timr (Remaining time)
The timer can be activated to display the time
remaining for each programme, provided that the
thermal stop, Express and extra rinse functions are
switched
off.
(deactivated by defect)
3.9
Parameters (In run mode)
To go to the menu and view the real data while the
machine is running, press INC and DEC ( , ) together
for 2 seconds.
PARA
water and remaining time.
IN
OUT
10
ON
activated,
OFF
Parameters: Temperature, level of
Inputs (technical service)
Outputs (technical service)