Descargar Imprimir esta página

Hiltron security FX30D Guia De Inicio Rapido página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

FX30D
CONNECTIONS
Automation
central unit
FUNCTIONING CHANNEL
The channel (Channel A or Channel B) is selected by a configuration
jumper and prevents the possibility of interference between two couples of
photocells that are operate in the same working area (for ex. Installation of two
couples of photocells on sliding gate).
After installation
Check that there is no voltage.
Wait approx 15 seconds to make the condensers unload.
Select a couple of photocells on the Channel A for the other couple
choose the Channel B using JMP1 as in figure.
Supply power to the photocell.
In this way, also if illuminating the receiver Rx2, the photocell Tx1 never realizes the alignment
condition because Tx1 and Rx2 are configured on two different functioning channels.
The same condition is valid for Tx2 and Rx1.
Rx 2
Rx 1
RECEIVER LED FUNCTIONING (Rx) / TRANSMITTER (Tx) :
The RED signalling LED indicates the status of the alignement:
RED LED with fixed: absence of obstacles (aligned infrared beam)
RED LED flashing: presence of obstacles (not aligned infrared beam).
4
PCM100
PCM212
PCM130
Channel A
Channel B
JMP1
Channel A
CH.A CH.B
Tx 2
Tx 1
Channel B
CH.A CH.B

Publicidad

loading