Descargar Imprimir esta página

TONON EVOLUTION HEAT CONCEPT Instrucciones Para El Instalador página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
ATTENTION
GB
• Before installation verify the integrity of the radiator.
• Each radiator is supplied with an installation kit and vents.
• After the installation, make sure that the radiator is stable and secure.
• The installation must be carried out according to the instructions in this manual.
• Max operating pressure: 6 bar
• In the case of operation with electrical integration, follow the instructions provided with the
Electric Res. kit.
• The heating water must have a temperature between 30 and 90°C.
• Before starting the installation, check that all the radiators are properly vented.
• Any noises during operation may be caused by the presence of air in the water by the
excessive speed of the water.
• The manufacturer declines all responsibility for any damage to persons or property resulting
from improper installation or improper use of the radiator.
CENTERING JIG
A) HOLES TO BE DRILLED IN THE WALL B) HARDWARE TO BE POSITIONED ON THE RADIATOR
A
INSTALLATION SEQUENCE (see last page)
1. Drill four holes in the wall using a Ø10 mm bit.
Then insert the dowels into the holes.
2. Place the base over the holes and fix them with the screws. The bases must be installed with
the slot facing up for the upper ones and vice versa for the lower ones.
3. Hook the two claws to the radiator according to the diagram.
The claws must be tightened with the screws supplied as standard.
Attention should be paid to the direction of installation of the claws: the upper ones should be
oriented with the holes upwards; vice versa for the lower ones.
4. Install the vent valve.
5. Attach the radiator to the bases positioned on the wall, fixing them with the screws.