A System presentation
ZOE timer-thermostats are designed to work alongside
ZONING SYSTEM control units in order to control
temperature for up to 6 different zones.
The ZOE timer-thermostat communicates with the control
unit. The central unit manages one or several motorised
gates (which regulate the airflow), as well as starting up/
shutting down the climate control unit, which provides the
airflow.
B Technical characteristics
ZOE thermostat (transmitter)
•
Power with two 1.5 V LR06 AA batteries (alkaline).
Average battery life 1 year (or longer). The batteries are
supplied with the equipment.
•
Battery life indicator.
•
Carrier frequency (ISM band, Standard I-ETS 300-220):
433.34 MHz (Optional: 434.92 MHz)
•
Medium range: 50 m in free field, 20 m in habitat.
•
Operating temperature: 0ºC to 55ºC.
•
Storage temperature: -10ºC to 60ºC.
•
Wall mount with bolts (supplied).
•
Protection grade: IP 20.
•
Economy ECO mode (±3ºC setpoint temperature
variation).
Control unit (receiver)
•
Power 230 VAC, 50/60 Hz.
•
KSP consumption: 4 VA, KRCPLUS: 14 VA.
•
Medium range: 50 m in free field, 20 m in habitat.
•
Orientable external antenna.
•
Carrier frequency (ISM band, Standard I-ETS 300-220):
433.92 MHz (Optional: 434.33 MHz)
•
Work cycle <10%.
•
Receiver, Class III.
•
Protection grade: IP 20.
•
Electrical insulation protection, Class II.
•
Operating temperature: 0 ¬½C to 55¬½C.
•
Storage temperature: -10 ¬½C to 60 ¬½C.
MADEL ATD hereby declares that the KRCPLUS / KSP /
KFCPLUS units comply with the essential requirements
and any other applicable or obligatory provisions of
Directive 1999/5/EC.
Timer-thermostat ZOE
C Location of the thermostats (fig. 1)
Fig. 1 Location of the thermostats
•
Place the thermostat in a significant location.
•
Place at a height of approximately 1.5 m, avoiding direct
heat sources and unwanted air currents.
•
Avoid placing the thermostats close to metal masses
and conductor elements.
ZOE time thermometers are powered by batteries,
meaning connections are not necessary.
D Battery change (fig. 2)
When the thermostat display shows the low battery
indicator, you have approximately 2 weeks to make the
change.
•
Remove the front cover from the thermostat, pressing
the tab in the top with a thin pointed tool.
•
Change the batteries; use alkaline batteries for longer
life (LR06 AA).
Fig. 2 Battery change
v
0.V
03/160
ubicacion
11
ZOE Timer-thermostat