7. Use
7.1
Charging battery pack
Push the battery pack completely to the stop on the sliding seat (1).
The operating indicator (2) flashes.
Note: have the charge level displayed on Li-ion battery packs, first take the
battery pack out of the charger and then press the button on the battery pack.
7.2
Conservation charge
Once the charging process has finished, the battery charger automatically
switches to conservation mode. The battery pack can remain in the battery
charger and is therefore always ready for use.
The operating display (2) lights up continuously.
8. Faults
8.1
Warning display (3) lights up continuously
Battery pack is not charged. Excessive/insufficient temperature. When the
temperature of the battery pack is between 0 °C and 50 °C, the charging process
begins automatically.
8.2
Warning display (3) flashes
• Battery pack is defective. Remove the battery pack immediately from the
charger.
• The battery pack was not pushed correctly onto the sliding seat (1).
See chapter 7.1.
9. Repairs
Repairs to the charger must only be carried out by qualified electricians. If the mains
connection cable of this device is damaged, it must be replaced by the manufacturer
or the Customer Service department of the manufacturer or a similarly qualified
person to prevent endangering personnel and property. If you have MontiPower
charges that require repairs, please contact your MontiPower
See www.montipower.com for addresses.