Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a
minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.
If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar
qualified personnel in order to avoid any malfunction.
Only suitable for indoors.
Replaceable LED
Replaceable driver
Replaceable receiver
Do not throw away electrical products together with household waste. We ask you to recycle the packaging
at the collection points provided for this purpose. Contact local authorities or your provider for recycling
advice. Thank you for recycling at the collection points provided for this manual.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
Nominal voltage and frequency
Light wattage
Luminous flux
Light color temperature
Nº of light ON/OFF cycles
Nº of hours of light lifespan
Protection category
Protection index
10
Word temperature
Dimmable/Not dimmable
Maximun ceiling slope on which it can be installed
Light angle
Light Ra
Weight
This product have a light source of energy efficiency class
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Service value SV ((m³ / min) / W)
Maximum air speed (m / sec)
Power consumption in standby mode (W)
Service value measurement standard
Preparing for installation
Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
CIF A28763647
220-240V~AC 50/60Hz
1
2
3
3,6
8
14,4
56
90
115
75
91
108
33
34
35
21
11
7,5
+34 916774540
Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)
Remote control
Syncing the receiver and the remote control for fan operation
If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver
recognizes the signal from the transmitter, this is called the learning process.
Make sure the fan is disconnected. This is essential for the synchronization process.
Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have
been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.
18W
If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note
1600lm
in any case that there could be other reasons why your fan or remote control does not work:
Make sure all connections are correctly made.
3000,4000,6000K
Make sure that the remote control contains batteries.
15000
Make sure that all switches (main and isolation) are on.
20000h
Instructions for synchronizing the receiver and the remote control
Class I
The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver;
IP20
Universal mode and Unit mode:
-5
40ºC
↔
- Unit Mode:
No dimmable
This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.
15º
Synchronization:
The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver
120º
- Universal Mode:
>80
This type of synchronization allows you to control one or more nearby fans with the same remote control.
6,2kg
Synchronization:
1.-Connect the power (wall switch) of the fan or fans that you want to control, and then just within the following
F
15 seconds, press the key
2.-A "beep" sound indicates that the connection has been executed and the equipment can function normally.
4
5
6
3.-Now, transmitter and receiver of the fan / s will have been synchronized. Turn off the fan / s current using the
switch or automatic and then turn it back on / s, this step is the one that closes the synchronization process.
22
29
40
It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave
132
145
158
to obey a command, another one must be linked to "overwrite it".
129
152
200
Remote control safety functions
36
37
38
5,8
5,2
5
Blocking protection
3m/s
The remote receiver includes a function that automatically blocks motor operation, cutting current to the motor 30 seconds
after detecting an obstruction in front of the fan that prevents normal operation. When this happens, you must remove the
<0,5
obstacles blocking the fan. Then, press the off button on the remote control to reset the receiver. Now you can continue to
EN 62879:2020
use the fan normally.
Note: Unless you remove the obstruction blocking the fan, it will not operate correctly.
Overload prtection
If the fan's receiver detects that the motor is operating at greater than 80W (this indicates an overload), current to the motor
will be cut automatically, which will immediately stop the fan. To reset the receiver, press the off button on the remote control.
Note: If the receiver goes into protection mode again, this may indicate a motor defect. Contact the supplier immediately. The
duration of the warranty is indicated in the warranty document provided in this manual.
ATC: 916749481 - info@sulion.es / SAT : 916749483 - sat@sulion.es
of the remote control for 10 continuous seconds.
11
www.sulion.es