Descargar Imprimir esta página

dormakaba LA GARD 700 Basic Instrucciones De Operación página 5

Ocultar thumbs Ver también para LA GARD 700 Basic:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Other Features
Wrong Try Penalty
Entry of 4 consecutive invalid Combinations initiates a 5-minute delay penalty.
During this penalty period:
• Keypad LED will flash every 10 seconds.
• Keypad will not respond to use of number keys.
After 5-minute delay, 2 consecutive invalid Combinations will initiate another 5-minute penalty period. This will continue until a valid
Combination is entered.
Low Battery/Battery Replacement
It is recommended to change batteries once a year. Use only high quality 9-volt Alkaline batteries.
Low Battery Warning – Keypad will repeat signal 5 times during lock opening.
should be replaced.
Critical Low Battery Warning – Keypad respond to any key press by repeating this signal 10 times
lock cannot be safely operated. The batteries must be replaced before the lock will operate.
Mechanical Reset with Reset Box
A mechanical reset can be done utilizing the LA GARD Reset Box (PN 704065) When reset using the 700 Series Reset Box, a lock can be reset to
these Default Settings:
• Super Master Reset Code will return to default 55555555 and must be set prior to changing the Manager Combination.
• Manager Combination will return to default 123456.
• No Active User will Exist.
Once the Reset Box is connected to a safe lock, deleted users cannot be recovered. All settings will be restored to the default values. While
the Reset Box is connected to the lock, ALL communication from the Keypad is rejected. Access to the secured area MUST be maintained
(keep the access door open) until the Reset Box is disconnected from the lock. If the access door is closed, the lock will have to be drilled to
re-open.
To perform a reset using the Reset Box
1. Remove Batteries or Disconnect the lock from any power source.
2. Press and hold the 0 key for 10 seconds to discharge any residual energy.
3. Connect the Reset Box to the Safe Lock BAT port.
4. The Reset Box LED will illuminate for approximately 3 seconds and then stop when the reset is complete. Do not unplug the box before the
reset is complete.
5. Disconnect the Reset Box from the Safe Lock.
6. Once Successfully reset, the Manager Combination will be reset to the default 123456 and the Super Master Reset Code will return to
default 55555555.
7. Reconnect power to the lock. Test by opening the lock with the default Manager Combination of 123456.
Note: If the Reset Box LED does not turn on. Disconnect the Reset Box and repeat steps 1 and 2.
Firmware Upgrade
When a new firmware is available, these files will be available to LA GARD Software users. Using the LA GARD Software client, keypad and lock
firmware can be updated. To update the Lock and Keypad Firmware to the current version, the Manager will require a PC with 700 Series
Software, a 700 Series USB Dongle (PN 7047040), and a USB to Mini USB Cable (PN 203325).
1. Connect the Keypad to the PC. Plug the 700 Series USB Dongle into the USB Port of the PC. Plug the USB port of the cable into the dongle.
Then plug the Mini USB into the port on the lock Keypad.
2. Enter the Manager Combination and hold the last digit for 3 seconds
3. Press 6.
LED remains on. Note: The unit is in Firmware Load Mode for about 60 seconds. During this period, the unit will ignore any
inputs from the keypad to allow communication between the software and the unit.
4. Use the software to select and upload the latest 700 BASIC firmware file. LED remains on until connection is established. If no connection is
established within 60 seconds, it will time out and the LED will turn off. Once the connection is established, the keypad LED will blink green
throughout the entire update process.
5. The Keypad LED will stop flashing green to signal that the firmware update is complete.
Note: 700 Basic Locks and Keypads are only compatible with 700 Basic Firmware. 700 Basic Firmware is not compatible with other 700 series
models. If an incompatible firmware is chosen, the 700 Series Software will display an error and maintain the connection until the compatible
firmware is selected. To clear the error, select the appropriate firmware and complete the update.
If an incompatible command is selected, the lock may respond with a Red LED that may remain on for up to 20 seconds. During that time the
keypad will not respond to key presses.
Any questions? We would be happy to advise you.
Contact us: sales.safelocks.us@dormakaba.com
dormakaba USA Inc. | 1525 Bull Lea Road, Suite 100 | Lexington, KY 40511 | +1 859 253 4744 | +1 888 950 4715 (toll free) | dormakaba.us
x5 This warning indicates that the battery is low and
LED remains on.
x10 This warning indicates that the
lg700basic.op.instruct.june2023
701.0722 Rev A

Publicidad

loading