Descargar Imprimir esta página

GRE AR20753 Manual De Instalación Y Mantenimiento página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
PROBLEMS
PROBLEMS
Green Light does not light.
Amber led is lighten (alarm).
Red led shines at 1 to 2 minutes
intervals.
Resistances do not work with
amber Light off.
ORIGIN
Electric supply is
not working.
Led is fused.
Thermostat
is
damaged.
Low water flow
or
air
in
the
system.
Thermostat
is
impaired.
Resistances
are
out of order.
Flow switch not
working properly.
ARS out of order.
6
ENGLISH
SOLUTIONS
Check and fix the electric
supply if necessary.
Check and replace the led
if necessary.
Replace
or
fix
thermostat, then restart the
heater.
If alter restarting the amber
light keeps shining or we
are not able to restart then
the
security
switch
damaged and must be
replaced.
Backwash the filter to
restore flow.
Fix unusual air entry.
Check
and
replace
necessary.
Check resistance between
two poles of resistance
fork
48Ω for 3Kw
25Ω for 6Kw
16Ω for 9Kw
12Ω for 12Kw
22Ω for 18Kw
Replace resistances if thy
do not reach those values.
Check
flow
operation.
Check for continuity with
paddle pushed. Replace if
necessary.
Check with continuously
activated (not intermittent)
flow
switch,
after
minutes, the resistances are
not turned on. If flow
switch is working properly
then replace ARS.
the
is
if
switch
1,5

Publicidad

loading