T EC HN IC A L I N F ORMAT IO N
Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Flow rate - lavatory
Flow rate - bidet
Hole size in mounting surface
Max. depth of mounting surface
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
I NSTA LL AT I O N CO N SID E R ATI ONS
⁄ For best results, Hansgrohe recommends that this unit
be installed by a licensed, professional plumber.
⁄ Inspect this faucet thoroughly before installation.
Claims for shipping damage made after installation
will not be honored.
⁄ Please read over these instructions thoroughly before
beginning installation. Make sure that you have all
tools and supplies needed to complete the installation.
⁄ MODEL 36120XX1 ONLY: The discharge water tem-
perature from a bidet fitting shall be limited to a maxi-
mum temperature of 110ºF (43ºC) by a water tem-
perature limiting device conforming to ASSE 1070.
⁄ MODELS 36103XX1, 36104XX1 ONLY: This faucet
does not include a drain or a pull rod.
⁄ MODELS 36100XX1, 36120XX1 ONLY: The drain is
suitable for most, but not all, lavatory sinks sold in the
United States and Canada.
15 - 75 PSI (0.1 - 0.5 MPa)
145 PSI (1 MPa)
120°-140° F (48° -60° C)*
158°F (70° C)*
1.2 GPM (4.5 L/min)
2.2 GPM (8.3 L/min)
1⅜" (35 mm)
1⅜" (35 mm)
E N G L I S H
⁄ This drain is intended for use in a sink with an over-
flow. If your sink does not have an overflow, or if this
drain is too small for the hole in your sink, please refer
to the instructions included with the sink. Some sinks
include special drain installation instructions and/
or parts. Others require the use of a specialty drain.
Hansgrohe is not respnsible for the cost of a specialty
drain.
⁄ The hot and cold supply hoses included with this fau-
cet are for use with ⅜ stops. If your stops are a differ-
ent size, install new stops. Adapters are not available
from Hansgrohe.
⁄ Keep this booklet and the receipt (or other proof of
date and place of purchase) for this product in a safe
place. The receipt is required should it be necessary
to request warranty parts.