WARNING
The products described in this manual are kerosene
direct-fired, forced air heaters. Kerosene forced air
heaters are primarily intended for use for temporary
heating of buildings under construction, alteration or
repair. Direct-fired means that all of the combustion
products of the heater enter the heated space. This
appliance is rated at 98% combustion efficiency, but
does produce small amounts of carbon monoxide.
Carbon monoxide is toxic. Humans can tolerate only
small amounts of carbon monoxide and so precautions
DANGER
should be taken to provide proper ventilation. Failure
to provide proper ventilation in accordance with the
instructions in this manual can result in death.People
with breathing problems should consult a physician
before using this heater. Early signs of carbon monoxide
poisoning resemble the flu. Symptoms of improper
ventilation/carbon monoxide poisoning are:
Headache • Dizziness • Nausea • Dry Mouth Sore
Throat • Burning of Nose and Eyes
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater serviced
and check for proper ventilation. Some people are
more affected by carbon monoxide than others. These
include: pregnant women, those with heart or lung
problems, anemia or those under the influence of
alcohol or at high altitudes.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
FOR: The temporary heating of adequately ventilated
buildings or structures under construction, alteration
or repair. Provide at least a three square foot (2,800
sq cm) opening of outside air for every 100,000 Btu/
Hr (29 kW) heater rating. Refer to "Ventilation" on
page 6 for further instructions.
© 2021 Pinnacle Climate Technologies, Inc.
All manuals and user guides at all-guidesbox.com
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
SAFETY INFORMATION (CONT.)
RISK OF INDOOR AIR
POLLUTION!
CARBON MONOXIDE
POISONING MAY LEAD
TO DEATH!
WARNING
ALWAYS use only the electrical power (voltage and frequency)
specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and extension
cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly exposed to
water spray, rain, dripping water, or wind.
NEVER use fuels such as gasoline, benzine, paint thinners or
other oil compounds in this heater.
NEVER refill the heater's fuel tank while the heater is
operating or still hot. This heater is EXTREMELY HOT while in
operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
WARNING
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
45-190T-KFA
Top
4 ft. (122 cm)
Sides
4 ft. (122 cm)
Front
8 ft. (244 cm)
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it is
plugged in, it can start at anytime in accordance with the
thermostat setting.
WARNING
CHILDREN, ANIMALS, CLOTHING AND COMBUS-
TIBLES AWAY FROM HEATER.
3
Kerosene Forced Air Heater User's Manual
RISK OF ELECTRIC
SHOCK!
RISK OF BURNS, FIRE
AND EXPLOSION!
215T-KFA
4 ft. (122 cm)
4 ft. (122 cm)
10 ft. (305 cm)
CAUTION! HOT WHILE
IN OPERATION. DO
NOT TOUCH. KEEP