Descargar Imprimir esta página

Vaporfi VEX 75 TC Manual página 6

Ocultar thumbs Ver también para VEX 75 TC:

Publicidad

Idiomas disponibles

Idiomas disponibles

EXTRA FEATURES:
1. NEW COIL/SAME COIL PROMPT
When replacing your atomizer, especially from a nickel atomizer to a temperature
controlled atomizer (Ni, Ti, SS 316), you will be required to reset the resistance of that
atomizer. This helps the device recognize that the new atomizer is to be used at room
temperature, which ensures that you will not experience a burnt hit, if properly
primed. When prompted press the + button to indicate that the replacement atomizer
is new. If you are using the same atomizer
2. LOCK/UNLOCK IN TEMPERATURE MODE
When using an atomizer in temperature control, to ensure that your atomizer is read
at the correct base resistance, you have the ability to lock your resistance. Press the
power button three times to enter the menu. Then press the – button to enter the
second row of your display, you will notice the resistance display is now blinking. Now,
press the + button to lock the resistance.
Note: It is important to unlock your atomizer's resistance before replacing the
atomizer. This will ensure that the new atomizer is installed at room temperature.