PARAMETERS
1. Container Capacity: 4 gallon, 15 liters
2. Pump: mini-diaphragm
3. Maximum pressure: 65 psi
4. Charger: Input AC100-240v 50/60hz, Output DC12v 2a
5. Battery: 12v10ah
6. Net weight: 7.4kg
OPERATING INSTRUCTIONS
• After unpacking the sprayer carton, verify that all parts
conform to the packing list.
• Be sure to fully charge the battery prior to operation
Charge Indicator
• Prior to use, twist off the tank's cap and slowly pour the fluid
through the filter into the tank.
• Close the cap securely and turn on the power switch.
• Place the sprayer carefully on your back.
• Squeeze the handle to begin spraying.
• Squeeze the handle for point-and-spray operation, or slide
down the lock switch for a continuous spray.
Continuous
Spray Switch

TROUBLESHOOTING

PROBLEM
The motor fails to run after
being powered on.
Abnormal sound heard in
the motor.
Leakage occurs in the bottom of
the base.
Poor performance
Battery Operated
Backpack Sprayer
CAUSE
• The battery needs to be charged.
• The power cable
has disconnected.
• The power switch has
been damaged.
The pump fastening screws
are loose.
• The inlet and outlet tubes of the
pump are damaged.
• Loose tube connection.
• The nozzle is clogged.
• Spraying hole and O-ring is worn.
• Seal is upside down.
• Filter screen is clogged.
• Leakage occurs at tube joints.
• Low battery.
• Air remains in the pump.
CLEANING AND MAINTENANCE
• After use, be sure to wash the sprayer surface. The tank
should be cleaned thoroughly with water to prevent sprayer
corrosion or spray head clogging.
• Clean the sprayer surface with a wet cloth.
STORAGE
• Power off the unit before storing.
• The sprayer should be stored in a dry, indoor area out of the
reach of children.
• To avoid battery damage, make sure to stand the sprayer
upright at all times.
• Recharge.
• Disassemble the base to reconnect the
cables securely.
• Replace the switch.
Tighten the screws.
Disassemble the base and tighten the
tube's connection.
• Remove and clean the nozzle.
• Replace O-rings.
• Place the seal in the proper position.
• Wash with clean water.
• Tighten screws.
• Charge the battery.
• Remove the nozzle or lance to discharge the air.