TECHNICAL CHARACTERISTICS
Power supply: 12 Vdc
with reverse polarity, interference and
overvoltage protection.
Absorption: MAX 65 mA.
Max ripple.: 1 Vpp.
And detector function: TIME-OUT 16 sec.
Scanning radius: > 90°.
Optic systems:
- Low diffraction fresnel lens with 28 stepped sectors
- 3 sector mirror for vertical scanning
Range: > 12 m.
Pyroelectric sensor: differential double element.
Microwave section: stripline with DRO
N.C. reed contact opening timing: Min. 1 sec.
Signals:
- ALARM: N.C. contact reed (0,5 A MAX)
- TAMPER: N.C. contact (0,5 A MAX)
- TEST/MEMORY:
- L1 (GREEN): Test IR
- L2 (YELLOW): Test MW
- L3 (RED): ALARM
Enable signal:
programmable (normally negative,or normaly positive)
Dimensions: 9 x 7 x 5 cm.
Weight: Approx. 120 g.
8
1) FITTING
Refer to fig. 1.
- Fix the bracket A or arm L to the wall in the position indicated
for the coverage required (height of detector mounting h= 2,5m).
- Fit the detector body C on the bracket or hinged arm.
- Connect the leads to the terminal board D and set SW1, SW2, SW3,
SW4 accordingly.
- Fit the cover G, securing it with the screw H and then the grill I.
2) TERMINAL BOARD CONNECTIONS
TERMINAL
DESCRIPTION
1 (+ ALIM)
Power input (10÷15 V
2 ( ALIM)
with reverse polarity, interference and overvoltages
protection
3,4 (ALL. N.C.) N.C. contact reed ( MAX. 0,5 A) for ALARM signal
5 (ABIL)
ENABLING command input (programmable)
6,7 (TAMPER)
N.C. contact ( MAX. 0,5 A) for signalling TAMPERING
3) PROGRAMMINGS
SW1: PULSE COUNT IR
SW1 ON
No pulse count
SW1 OFF
Two pulses in 16 seconds
)
9