EN
INFORMATION
8. TROUBLE SHOOTING
You can solve many common problems easily, saving you the cost of a possible service call.
Try the suggestions below to see if you can solve the problem before calling the service centre.
Problem
Possible cause
The heater does not
The plug is loose, bad
operate, even when it
connection
is plugged in and the
No power in socket
switch, thermostat are
outlet
switched on.
The input voltage is
too high or too low
The heating element
glowing
The air inlet grill is
blocked
The switch was not
put at heating setting
The thermostat
The appliance didn't
operated
heat up, or only
ventilator worked
The self-resetting
cut-out operated
The appliance is not
Abnormal noise
stands upright
Disposal Environmental Protection
Waste electrical production should not be disposed of with household waste.
Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice.
Treatment
Pull out the plug, check the connection of the
plug and socket. Then connect again.
Insert the plug in a proper socket
Use power supply according to
the rating on the label
Keep the heater far way from articles like
curtain, plastic bag, paper and other things
which can cover the inlet or can be easily cover
on the air inlet
Turn the switch to heat setting
Turn the thermostat and listen if there is
open/close voice. If there is no click and the
thermostat is not damaged, the heater will
automatic switch on when the appliance
cooled down
Turn the heater off and inspect the blockage of
inlet or outlet. Disconnect the plug and wait at
least 10 minutes for the protection system to
reset before attempting to restart the heater.
Put the heater on a level surface
Model identifier(s): GP 08 24
Item
Symbol
Value
Heat output
Nominal heat output
Pnom
2.4
Minimum heat output (indicative)
Pmin
1.2
Maximum continuous heat output
Pmax
2.4
Auxiliary electricity consumption
At nominal heat output
elmax
N/A
At minimum heat output
elmin
N/A
In standby mode
elSB
N/A
Contact details:
See cover page with contact information
Remark:
For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot be worse than the declared value at the nominal heat
output of the unit.
Unit Item
Type of heat input, for electric storage local space heaters only (select one)
kW
Manual heat charge control with integrated thermostat
Manual heat charge control with room and/or outdoor
kW
temperature feedback
Electronic heat charge control with room and/or outdoor
kW
temperature feedback
Fan assisted heat output
kW
Type of heat output/room temperature control (select one)
kW
Single stage heat output and no room temperature control
W
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
Electronic room temperature control plus day timer
Electronic room temperature control plus week timer
Other control options (multiple selections possible)
Room temperature control, with presence detection
Room temperature control, with open window detection
With distance control option
With adaptive start control
With working time limitation
With black bulb sensor
Unit
[no]
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[no]