highest point of the sterilizer.
In mounting the sterilizer, you may find handy the brackets (1), which
can be fixed to the background by means of suction caps (2) or screws.
Following the above preparations, you should first turn on the pump
cooperating with the sterilizer. Make sure that the hoses are tightly
connected to the sterilizer. If leaks are discovered, tighten up the con-
nections. Only after stabilizing the water flow, turn the sterilizer on by
sticking the plug in a power outlet.
In order to obtain optimum results, it is recommended to use the steril-
izer non-stop for the entire season from spring to late autumn. The UV-C
fluorescent lamp is expected to last up to 10,000 hours, so it will serve us
seamlessly throughout the season.. After the lapse of the planned period
of operation, the UV-C sterilizer should be turned off, by pulling the plug
from the power supply socket.
In order to get rid of algae from the pond, it is sufficient to use the UV-C
sterilizer in cycles, e.g. one month of operation and one month of inter-
val, and so forth.
ATTENTION! The device is equipped with a safety switch (mi-
croswitch) to protect the user from the harmful effects of possible ex-
posure to UV-C light. The moment the holder in the steriliser housing
(7) is turned on, the lamp is automatically switched off (the lamp in the
steriliser housing outside the steriliser module DOES NOT LIGHT).
Before starting the appliance, make sure that the socket is screwed
on as tight as possible and forms a single unit with the housing (7).
For efficient operation of the sterilizer, it should be cleaned every several
weeks, performing the following actions:
1. disconnect the device and the pump cooperating with it from the
power supply by pulling the plugs from the sockets,
2. disconnect the device from the waster circulation and remove any
water remaining in it,
3. remove the luminaire with the fluorescent lamp by turning it anticlock-
wise,
4. carefully remove the quartz cover (8) by gently sliding it out of the
lamp body (7) and rinse it under running water and carefully wipe it
dry – especially its inner side,
5. screw out the stub pipes (5) and stopper (3), remove the gaskets (4)
from them, and carefully clean under running water,
6. clean the housing,
7. assemble the device in reverse order, all gaskets must be properly
placed in their groove and greased with Vaseline, and the fluorescent
lamp must be inserted all the way into the fitting until refusal.
FLUORESCENT LAMP REPLACEMENT
When the UV-C fluorescent lamp does not work it should be replaced
as follows:
LAUNCH AND USAGE
CLEANING THE STERILIZER
STERILIZERUV