DR90 Specifications
Install DR90A3000 according to National Electric Codes.
Dry-Bulb Temp
80°F (26.7°C)
70°F (21.1°C)
60°F (15.6°C)
Home Size
(square ft [m])
2080 (193.2)
2600 (241.5)
3120 (289.9)
* Based on extreme climates where outdoor humidity is 70-90% RH. For less extreme climates, larger
homes can be adequately served with less capacity. Actual requirements may vary.
Dimensions in inches and (mm):
14-3/4 (375)
19-7/8
(505)
Product weight: 86 lbs.
Shipping weight: 95 lbs.
Shipping dimensions: 25.2" H × 19.3" W × 35.8" L
Media Filter: MERV 11, 14" H × 17.5" W × 1.75" L
Drain connection: 3/4" threaded female NPT connection.
Duct connections: 10" round inlet and outlet. 6" supply inlet.
ABS plastic, compatible for connection to rigid or flexible
ducting with sheet metal screws and/or tape.
Cabinet: 20 ga
Insulation: R value 1
Compressor: Rotary, 7.3 KBTU
Refrigerant: R-410A, 25 oz
Operating Temp Range (outside cabinet):
34ºF to 135ºF (1.1ºC to 57.2ºC)
Operating Humidity Range: 0-99% RH
4
Intake Humidity
Capacity (Pints/Day)
60% RH
60% RH
60% RH
Dehumidifier Capacity Required to Maintain Desired Indoor RH*
60% RH Indoor
(pints/day)
49–54
61–68
75–82
3-1/8
(79)
25-7/8 (657)
90
65
47
50% RH Indoor
(pints/day)
55–58
65–72
79–86
Airflow versus external static
pressure (0–1 in. [0 - 25.4 mm] water
3-1/8
(79)
pressure) with collars attached
0 in. (0 mm)
0.2 in. (5 mm)
0.4 in. (10 mm)
0.6 in. (15.2 mm)
M38506
Input ratings
• Electrical input voltage: 120 VAC,
• Input current: 5.3 A
Output ratings
• Power transformer to R/C
• Energy Performance: 2.9 liters
Standards and approval body
requirements
• ETL Listed per UL 474 and
• ENERGY STAR rated.
DR90A3000/DR120A3000 Dehumidification System 33-00298EFS—15
40% RH Indoor
(pints/day)
71–78
90–97
95–110
320 CFM
280 CFM
260 CFM
215 CFM
60 Hz nominal
terminals: 24 VAC, 0.85 A
(6.1 pints) per kilowatt hour (KWH)
CSA C22.2 No 92