CyberPower UT550G Manual Del Usuario página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

LED
Light
ON
Yellow
Flash
ON, Flash once
every 5 seconds
ON, Flash twice
every 5 seconds
ON, Flash 3 times
Red
every 5 seconds
ON, Flash 4 times
every 5 seconds
Flash
Model
Capacity (VA/W)
Input
Voltage Range
Nominal Frequency
Output
On Battery Output Voltage
On Battery Output Frequency
Overload Protection
Physical
Total UPS Receptacles
Dimensions (W x H x D)(mm)
Weight
Battery
Sealed Maintenance Free Lead Acid Battery
Typical Recharge Time
Warning Diagnostics
Indicators
Audible Alarms
Environmental
Operating Temperature
Operating Relative Humidity
Problem
The UPS does not perform
expected runtime.
The UPS will not turn on.
Outlets do not provide
power to equipment.
Copyright © 2021 Cyber Power Systems, Inc. All rights reserved.
Audible Alarm
Beep twice every 30 seconds
Rapid Beeping
Constant Tone
Constant Tone
Constant Tone
Constant Tone
Constant Tone
TECHNICAL SPECIFICATIONS
Possible Cause
Batteries are not fully charged.
Battery is slightly worn out.
The unit is not connected to an AC outlet.
The battery is worn out.
Mechanical problem.
Fuse is blown or breaker is tripped due to
overload.
Batteries are discharged.
Unit has been damaged by a surge or
spike.
CyberPower Systems (USA), Inc.
4241 12th Avenue East, Suite 400
Shakopee, MN, 55379
Phone: (952) 403-9500
Fax: (952) 403-0009
www.cyberpowersystems.com
UPS Status
Battery Mode
Low Battery
Battery Output Short Fault
Overload Fault
Charger Fault
Hardware Fault
Overload Warning
UT550G
550/275
84 mm x 174 mm x 280 mm
3.800 kg
RBP0119 x1
6 Hours to 90% from total discharge
Utility / Battery / Fault
On Battery, Low Battery, Overload, Fault
TROUBLESHOOTING
Recharge the battery by leaving the UPS plugged in.
Contact CyberPower Systems Technical Support.
The unit must be connected to a 120V outlet.
Contact CyberPower Systems Technical Support.
Contact CyberPower Systems Technical Support.
Turn the UPS off and unplug at least one piece connected equipment. Unplug
the power cord of the UPS then replace the blown fuse with a spare one or
press the circuit breaker knob. Connect power cord then turn the UPS on.
Make sure that your spare fuse meets the specification.
Allow the unit to recharge for at least 4 hours.
Contact CyberPower Systems Technical Support.
Description
The UPS is providing battery power.
The UPS will run out of battery power soon.
Turn off the UPS and unplug at least one piece of
equipment.
Connected equipment exceeds the rating of the unit.
Turn off the UPS and unplug at least one piece of
equipment.
Contact CyberPower for support
Contact CyberPower for support
Connected equipment exceeds the rating of the unit.
Turn off the UPS and unplug at least one piece of
equipment.
UT750G
750/375
86~148Vac
50/60Hz +/-5Hz
120Vac
50/60Hz +/-1%
Circuit Breaker
NEMA 5-15R x 8
4.000 kg
RBP0143 x1
0C to 40C
0 to 90%
Solution
All rights reserved. Reproduction without
permission is prohibited.
UT1000G
1000/500
4.200 kg
RBP0089 x1
K01-C000496-01