PROBLEM
POSSIBLE CAUSE
• Error codes
Front panel displays
- "E0", "E1". "E2",
"E3",
"E4", "E5", "E6".
Front panel displays
Indicates the door switch failure
- "E7".
• Has the door been open for more than 60
The alarm sounds
seconds?
and the display is
flashing
If not, the temperature has risen or has
fallen below the temperature established.
This may have been due to:
• The door is opened very often.
• The ventilation opening is obstructed or
contains too much dust.
• A long power cut.
• Many of bottles have just been added to
the unit.
• Has the door been open for more than 60
The alarm sounds
and the display
seconds?
panel DOES NOT
blink. (door alarm)
The icon "-" is lit up
• The temperature on the Display is out of
and blinking on the
range.
display
Condensation
on
• High Humidity in the environment
the outside of the
door glass
The display
• Differential
temperature does
between both zones is out of range.
not correspond to
the real one
Greater than 10 ° C
temperature
relationship
35
WINE CABINETS
SOLUTION
• Try to restore the controls with a
"Reset". (Disconnect from the mains for
5 minutes)
• If the problem persists, call Technical
Service.
Check that the door closes properly
and that the sensor is not dirty or
obstructed.
• If this is the case, close the door.
• Do not open the door more than
necessary.
• Remove the obstructions and clean out
the dust.
• Let the device work for some time
until it has reached the selected
temperature.
• Close the door or press the POWER
button to turn off the alarm. The alarm
will stop when the door is closed
• The appliance only shows temperatures
within a range of 0 ~ 99 ° F /-9 ~ 37 ° C.
If the temperature is not within this
range, the icon "-" with be displayed
instead.
• During periods of high humidity, it may
appear drops of water on the outside of
the door glass. These will disappear
when the humidity level drops. It is
advisable to install the unit in a place
with sufficient ventilation, in a dry place
and / or with air conditioning.
• Lower temperature difference between
zones.