CONTROLS
Choke control
The choke control is used for cold starts to supply
the engine with a richer fuel mixture. For cold
starts the control should be pulled up.
Ignition Switch
The ignition switch is on the control panel and is
used to start and stop the engine.
Service Meter
The service meter displays the total number of
hours the engine has run and indicates when the
engine and mower need servicing.
After every 50 hours of operation, an oil can icon
will appear and stay on for two hours, before an
automatic reset occurs. To manually reset the
meter, turn the key off and on five times at one
second intervals. To service the engine and mower,
see the Service Journal of this manual.
NOTE: The service meter operates (clocks hours)
only when the ignition is on. Be sure to turn the key
off when the unit is not in use, to prevent meter
hours from accumulating.
14
Blade Switch
To engage the mower deck, pull the knob out;
mower blades are disengaged when the knob is
pushed down.
Fuel Shut Off Valve
The fuel shut off valve is located at the right rear
of the seat. The valve is off when the handle tab is
turned perpendicular to the fuel line.
Fuse
The 20 amp primary fuse is located on the left
hand side of the machine. It is accessed by tilting
the seat forward. The fuse is a flat pin type used
in automobiles.