29 / EN
7.
Once the above has been completed, you can power the heater to start its
operation. Never omit the electric circuit's ground connection. (see Figure 7)
(Grounding Diagram). We recommend connecting the green ground wire to a
copper rod (copperweld).
8.
Grounding the appliance is obligatory, and the cable must be fixed to the ground
connection.
VIII. HEATER OPERATION
Before using your water heater, make sure you read and follow the instructions in this
manual and all the product labels.
W ARNING! Make sure your heater is completely full of water before turn it on; if you
turn on your heater without water, it will damage the electrical resistance (heating
element), and will void the warranty.
Operation and Temperature Regulation.
Turning the heater on/off
The water heater is turned on and off with the regulator knob, and not by connecting or
disconnecting the equipment from the electrical power connection.
The light indicator stays on only during the heating phase.
Grounding Diagram
Wire
Copper rod
(Copperwed), ½"
diameter x 1 m length
FIG.7