IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA-
TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK-
ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "installers of electrical
equipment" and must respect the local standards and regulations in force. All
materials used must be approved and must suit the environment in which the
installation is situated.
• All maintenance operations must be carried out by professionally qualified techni-
cians. Before carrying out any cleaning or maintenance operations make sure the
power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been
made. "i.e. for the automation of hinged gates" with one or two gate leaves.
• The unit may be fitted both to the right and to the left of the passageway.
This product and all its relative components has been designed and manufactured
by Cardin Elettronica who have verified that the product conforms in every aspect
to the safety standards in force.
Any non authorised modifications are to be considered improper dangerous and
the complete responsibility of the installer.
Caution! Mechanical stop buffers must be installed in both the closing
and opening positions. (pos. 1, fig. 5).
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road
to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property at a height between 1,5
and 1,8 m and not on the public side of the gate. The gates must not open onto
a public area.
3) The gate operator is designed for use on gates through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The gate must be in full view when it is operating therefore controls must be situated
in a position where the operator can see the gate at all times.
5) At least two warning signs (similar to the example on the right)
should be placed, where they can be easily seen by the public,
in the area of the system of automatic operation. One inside the
property and one on the public side of the installation. These
signs must be indelible and not hidden by any objects (such as
tree branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets
must not be allowed to play within the area of a gate installation. If possible include
this in the warning signs.
7) Whenever a fully open gate leaf comes within at 500 mm of a fixed structure the
space must be protected by an anticrush buffer.
8) You are advised to protect the system's lateral access points with pairs of (FS)
photocells connected to the stop input, see installation example, component 14
on page 2.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
200/BL1924ASW is suitable for the automation of hinged gates with one or two gate
leaves, max. length 2 m, max. weight 150 kg.
• Single piece geared reduction unit with an incorporated encoder.
• Direct current drive motor max. 28 Vdc.
• Permanently lubricated double reduction unit mounted on a cast iron stator with
a never ending screw.
• Irreversible reduction unit with a key-operated manual release mechanism.
• Carter in shock-proof plastic.
• Motor support base in zinc-plated steel
• Articulated operator arm in spray painted cast aluminium
ACCESSORIES
980/XLSE11C - Electric locking device 12 Vac/dc
IMPORTANT REMARKS
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has expired it
must be disposed of separately from other rubbish. The user is therefore
obliged to either take the product to a suitable differential collection site for
electronic and electrical goods or to send it back to the manufacturer if the
intention is to replace it with a new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment and disposal contrib-
utes to avoiding negative effects on the ambient and consequently health as well as
favouring the recycling of materials. Illicitly disposing of this product by the owner is
punishable by law and will be dealt with according to the laws and standards of the
individual member nation.
During the opening/closing manoeuvre check for correct operation and activate
the emergency stop button in case of danger. During blackouts the gate can
be released and manually manoeuvred using the supplied release key (see
manual release page 7).
Periodically check the moving parts for wear and tear and grease if required,
using lubricants which maintain their friction levels unaltered throughout time
and are suitable for temperatures of -20 to +70°C.
Periodically check the correct operation of all safety devices (photoelectric cells
etc.). Eventual repair work must be carried out by specialised personnel using
original spare parts. The appliance is not suitable for continuous operation
and must be adjusted according to the model (see technical data on page 48).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed in a location not accessible to children and outside
the opening range of the gate.
Before starting the installation of the system check that the structure which is
to be automated is in good working order and respects the local standards and
regulations in force. To this end make sure that the gate is sufficiently rigid (if
WARNING
necessary reinforce the structure) and that it pivots easily.
AUTOMATIC OPENING
KEEP CLEAR
You are advised to grease all the moving parts using lubricants which maintain
unaltered friction characteristics over a period of time and are suitable for
temperatures of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
- a minimum space of 30 mm must always be left along the entire distance
between the gate and the support column measured throughout the entire
opening angle of the gate.
- make sure that the space between the bottom of the gate and the pavement
never exceeds 30 mm throughout the entire opening angle of the gate.
• The surface of the gate must not feature openings which allow a person's
hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working order (the
upper and lower hinges/pivots must be aligned on the same axis).
• Work out the run of the cables according to the command and control devices
fitted and make sure the system conforms to the local standard and regula-
tions in force (see installation example fig. 1 page 2).
• Check that the appliance is suitable for the size, weight and duty cycle of the
gate to which it is to be applied (see duty cycle on page 48).
ASSEMBLY PROCEDURE
The unit may be positioned either to the right or to the left of the passageway:
• Move the gate/s to the closed position.
• Choose the value "A" (fig. 4) according to the required opening angle and
work out (depending on the structural characteristics of the gate) at what
height the front bracket will be fitted to the gate. Once the position has been
established, fasten down the motor support plate using four M8 screws and
steel Ø14 rawlplugs. Make sure that the support bracket "D" (fig. 7) is in
square.
• Insert the operator arm "E" onto the motor drive shaft as indicated in fig. 8
and tighten down using the supplied grub screw "F".
• According to the assembly drawings (motor installed to the right fig. 9) and
(motor installed to the left fig.10) fix the geared motor to the base plate using
17