VESTA7 G 2
B - V
ESTA
7 GB2/H
SAFETY PRECAUTIONS
- Always disconnect the power supply before making modifications to the device.
.
- The fitting and handling of these devices must be carried out by authorised personnel.
.
- The wiring must run at least 40 cm away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the system to the mains, check the connections between the door panel, power
supply, distributors and monitors.
- Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
- Hands-free monitor.
- 7 TFT colour screen
"
.
- Monitor with simple installation (unpolarised 2 wire BUS).
- Capacitive function buttons to access and select menu functions.
- User menu.
- Installer setup.
-
Screen and volume settings menu
.
- Start / stop communication push button.
- Door release push button.
- Status LEDs.
- Dip switches for setting the address monitor (call code) and end of line.
( )
SYSTEM OPERATION
*
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. If vocal synthesis is enabled, a "Call is in progress"
message appears to indicate a call is being made. At this moment the apartment's monitor(s)
receives the call. During the call the visitor can correct his call by pressing a push button
corresponding to a different apartment, in which case the original call is cancelled.
- The ring tone lasts for 40 seconds. Without alerting the visitor, their image appears on the master
monitor during this time.
House kit application
"apartment 1" or monitor with code 16 if the call is in "apartment 2") when receiving the call
without the visitor being alerted.
If the call is not answered within 40 seconds, LED
- To establish communication, press button
LED will turn on. If monitor is the VESTA7 GB2/H with symbol
at a distance of 20 cm from the monitor to obtain the maximum audio quality during communication
with the door panel.
- Communication will last for one and a half minutes or until button
communication has finished, LEDs
and
synthesis is activated, a "Communication is finished" message will indicate that the call is over.
- To open the door 1 or 2 press the push button
processes: one press will activate the lock release for five seconds and LED
for five seconds. If vocal synthesis is activated, a "Door Opened" message will be indicated on
the door panel.
-
Descriptions of the function push buttons can be found on page 3
( ) For more information, see the TVESTA7 GB2 user manual (code 50121960)
*
"
https://doc.golmar.es/search/manual/50121960
MONITOR
: the image appears on the monitor (with code
will turn off and the channel will be freed.
on any monitor in the apartment. Door panel
in front side,
place the hearing aid
or
is pressed again. When
will turn off and the channel will be freed. If vocal
/
during the call or communication
will also turn on
.
".
2
VESTA7 G 2
B - V
( )
DESCRIPTION OF THE MONITOR
*
c
d
e
a. 7" TFT colour screen.
b. Microphone.
c. Start / stop communication push button.
During standby: Display door panel image.
d. Door release push button 1. Standby: Exterior light
activation.
e. Door release push button 2. Standby: 'do not disturb' mode,
if the mode is activated, the icon illuminates
Vesta7 GB2 V06 & Vesta7 GB2 / H V05 and later: One press
for 3 sec. activates / deactivates the "do not disturb" mode.
f. End call/communication button.
In standby intercom function in the apartment.
In auto spy/auto switch-on: Selects other door panel(s),
camera(s) in descending mode and in carousel (if any).
g. In standby: Enters menu.
Menu push buttons:
Menu entry and user settings button.
Menu screen exit and selection button.
Menu entry and selection button.
( )
*
Monitor address (code) setup:
1-apartment kit
2-apartment kit
APARTAMENT 1
APARTAMENT 1
VESTA7
VESTA7
0
CODE 0
CODE 0
( )
1
2-apartment kit Monitor code 1 is the last,
:
dip 6 of the end of line to ON.
( )
INSTALLATION OF THE MONITOR
*
Location
1.60m
( ) For more information, see the TVESTA7 GB2 user manual (code
*
https://doc.golmar.es/search/manual/50121960
EN
ESTA
7 GB2/H
MONITOR
i
n
j
a
k
l
b
m
j
i
g
f
h
In auto spy/auto switch-on: Selects other door
panel(s), camera(s) in ascending mode and in
carousel (if any).
In call/communication: selects camera(s) in
ascending mode and in carousel (if any).
h. In standby: enters menu.
Video activated: screen
. Note:
settings
i. Vertical wiring entry.
j. Connector fixings.
k. Configuration DIP switch.
l.
Co nector.
n
m.Bus connection terminals.
n. Communication with hearing aids (Vesta7 GB2/H).
Put the hearing aid selector in mode . T
(contin
ued
)
On menu screen: shows door panel image.
On menu screen: Activates outdoor light.
On menu screen: Intercom function between
apartments.
Building
Dip6: Sets the end of line. Set to ON in monitors where the video cable
APARTAMENT 2
terminates. Remainder set to OFF.
VESTA7
Dip1
to
Dip5:
Set the monitor address (addresses to 3 )
The switches set to OFF have a zero value.
The values of the switches set to ON are shown in the table below.
The monitor code is the sum of the values of the switches set to ON.
( )
1
CODE 15
Value chart
Switch number : 1
2
3
5
Value when ON: 1
2
4
Surface
Embedding box
4 30
x
50121960)".
"
3
&
communication volume
0
1 .
ON
DIP
4
5
1
2
3
4
5
6
8 16
E
xample
: 0 + 0+4+0+16 = 20
Screws supplied with
the embedding box
EN