2
1
3
In T cell
Stick the vase of the cell and then takes up electrodes, the water tightness seal, grease before, and
hand tighten the nut.
Insert the cell in its vase and positioning electrodes perpendicularly in water flow direction.
Use, if it is necessary, supplied 60/50 reducers.
In case of connection on flexible tubing, stick one by one the fitting on the 63/40 mm reducers and then
stick the set on the supplied D63 collars.
Wait that all the stickings are totally dry before handing pipes under pressure.
Connect the cell supply cable to the controller box:
Position the 2 terminals (Brown and Blue) indifferently on one of the borders of cell.
Install the lock washers and the nuts, and then tighten nuts (using a size 10 spanner), gently, until the
blocking.
Put safety lids on theses connectors.
Incorrectly connected cell entails dommages even going so far to destruction. Guarantee doesn't be
used in this case.
CONNECTION TO A POOL COVER (depending on model; with optional cable)
3
In the controller of the pool cover, locate the limit switch (a dry contact, without any connection).
Some pool cover manufacturers specifically identify this switch for salt chlorinator control.
Connect with an electric cable (2 conductors) the dry switch of the pool cover in the connection box;
Optional cable allows the connecting of the device to the controller box of the pool cover. Do not
hesitate to get yourselves the cable (ref OPT07POO001) with your professional.
Plug the connector under the device on the yellow RCA jack.
MINISALT – PAPI004086MULTI – FR/EN/DE/IT/ESP/PT – Rev.05.16
The whole of pipe/cell/pipe has to be perfectly right at risk of water
leak at the level of cell's input or output