Troubleshooting Guide
PROBLEM
No power
Stays in "warm up"
mode
No detection
Slow recovery after
detection
No beeping
Partial list of detectable SNAP* listed refrigerants
R-12 ALTERNATIVES
R-134a, R-1234yf, R-401A (MP-39), R-401B (MP-66), R-401C
(MP-52), R-406A (GHG)
R-414A (GHG-X4), R-414B (Hot Shot), R-416A (Frig C, FR-12) R-113, R-13B & R-503 ALTERNATIVES
R-409A (FX-56), Freeze 12, Free Zone, GHG-X5, GHG-HP,
IKON 12
R-502, R-500 ALTERNATIVES
R-402A&B, R-404A, R-407A, R-408A, R-411A&B, R-507
* SNAP (Significant New Alternatives Program) an EPA program for ozone depleting refrigerants for mobile and stationary A/C systems
Parts kit (sensor, filters and leak standard bottle)
Sensor and filter
Sensor filters (package of 5)
Leak standard bottle
A/C Adapter Input: 115V 60Hz
A/C Adapter—EU/UK Plug Input: 230V 50Hz
CE & TÜV Approved
A/C Adapter—AU/NZ Plug Input: 230V 50Hz
CE & TÜV Approved
Battery cover and screw
Carrying case - blow molded with inserts
Carrying pouch
CHECK
Check for weak or reversed
batteries
Sensor not plugged into socket
correctly
Sensor open/defective
Check sensor with leak standard
bottle
Check if the filter is dirty or sensor
opening is plugged
Check if filter is dirty or sensor
opening is plugged
Nothing
UL listed
REPAIR OR REPLACE
Replace batteries
Make sure sensor is pushed all the
way down into socket
Replace sensor
Replace sensor
Replace filter or clean out opening
Replace filter or clean out opening
Press mute button (if equipped)
to turn speaker back on