Do not use cleaning products containing acids or chlorine (such as bleach), or abrasive materials (such as pads) or pressurized water
(such as hoses).
5.4. Condenser Cleaning
To ensure long life and correct operation of the refrigeration system, clean the condenser regularly as indicated:
Switch off the appliance and unplug it, or switch off the circuit breaker;
Unscrew and open the air vents grid; be careful with cable holder, do not stretch the cables;
Carefully vacuum (preferably) or brush the condenser coils;
Finally, screw back the air vents grid.
5.5. Extended Period of Inactivity
Where there is a foreseeable extended period of inactivity, remove all foodstuff from the appliance and clean it as described. In the end, switch
it off from the mains and leave the doors open to prevent bad odour.
5.6. Power cord replacement
IF DETERIORATED, THE POWER CORD MUST BE IMMEDIATELY REPLACED BY AN ORIGINAL ONE PROVIDED BY THE
MANUFACTURER OR BY AFTER-SALES SERVICE. THE REPLACEMENT MUST BE PERFORMED BY QUALIFIED PERSONNEL.
5.7. Noise emissions
Time-weighted of equipment noise emissions, in workplace, do not exceed 70 dB(A).
5.8. Troubleshooting
If you notice any malfunction, refer to the checklist below to identify the problem and its possible solutions. If the problem still persists, please
contact the after-sales service.
Equipment does not run and the display does not work
Equipment does not run but the display works
Equipment is not cold enough
Equipment is too cold
Equipment runs continuously
Equipment starts and stops frequently
MNS00059.00.DOC
PRT
Instruction Manual
Symptom
Make sure the plug is inserted into the socket
Check for a blown fuse or tripped circuit breaker
Test the power outlet for current
Inspect the electrical cord for damage
Remove any extension cord
Check the temperature setting
Assure that there is enough air flow inside the equipment
Clean the condenser coils
Check the temperature setting
Assure that there is enough air flow inside the equipment
Check for airflow restrictions in vents
Clean the condenser coils
Clean the door seals
Check for a clogged drain pipe
Check the temperature setting
Clean the condenser coils
Clean the door seals
Clean the condenser coils
N.º
MNS00059.00.DOC
Check
5/23