EN
•
Never spread more than 1000 kg.
•
Prop the load during spreading.
2.6
Safety regulations with respect to the operation of the system
•
Make a risk assessment of the procedure before you start work (EN-ISO 12100).
•
Keep bystanders at a distance and be extra careful in the vicinity of people and animals.
•
Make sure the work area is clearly laid out and has good lighting.
•
Avoid stress and work in a structured way. This reduces the risk of errors, combinations of dangers
and accidents.
•
Before use, check the equipment for damage. Do not use the equipment if it is not in good condition
and consult your Holmatro dealer.
•
Stand on a stable base and use both hands to hold the equipment.
•
During operation, never get between the object and the equipment.
•
Monitor the situation of the equipment and the structure continuously while using the equipment.
•
Parts of an object that could fly off must be secured.
•
Never couple or uncouple couplers while the system is under pressure.
•
Use only genuine Holmatro accessories and ensure that they have been attached correctly.
•
Make sure that parts of the body never come between moving parts. There is a risk that parts of the
body may be crushed or cut.
•
Stop immediately if the system makes strange noises or displays aberrant behaviour.
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
•
Return inactive equipment immediately to the tool station.
•
Always adhere to the safety regulations that apply to other equipment that is used in the operation.
2.7
Safety regulations with respect to maintenance
•
Wear personal means of protection when performing maintenance tasks.
•
Never work in a way that could jeopardize safety.
•
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
•
Make sure that moving parts do not move unexpectedly.
•
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
3
Description
3.1
Equipment
This is a single-acting hydraulic tool with spring return designed to be driven by a Holmatro hydraulic
hand or foot pump. The system operates with mineral oil at maximum 720 bar.
3.1.1
Type designation
Example: HW 1000
/i
Digit Example
Description
1-2
HW
Holmatro Wedge
3-6
1000
wedge code
20
916.219.177_004
HW