order # 60223101
60223201
60224101
Use and Care GUide
Led FLood LiGht instrUCtions
120-277V 50/60hz 100W/150W/205W 150W/200W/255W 250W/290W/330W
packaGe contentS
description
Quantity
Fixture
1
Yoke mount bracket
1
Screw
4
Gasket
1
Expansion screw
2
Shorting Cap
1
default setting is at highest wattage, 5000k cct
note: Keep your receipt and these instructions for proof of purchase.
note: To prevent from electric shock or fire risk, the installation must be conducted by operator who have professional electrical knowledge. Please wear gloves to avoid injury
before installing lamps. During or after installation, if there are situations such as smoke, fire in the wires or lamps, please turn off the power immediately and notify relevant
personnel of an overhaul. This light can be used for outdoor installation.
WarninG: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast, or fluorescent tubes. Can not use the electric generator to test the LED lamp.
Please abide by related country, regional and local law and regulations when install this fixture. To avoid electrical shock and damage, do not install the lights on rainy days.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
inStructionS
1. 3 dimming functions are available in this LED lamp:
• Constant current can be achieved by 1-10(or 0-10)V DC dimming.
• PWM signal dimming.
• Variation of resistance unit dimming(Please choose the appropriate dimming way according to your needs. You can also choose not to use this function).
2. Choose the wire connection ways, dimming ways and installation ways according to your needs and the led fixture purchased.
wirinG diaGram
For the wire color of
DIM+ and DIM-, check
the lamp label.
Black/Brown:ACL
Dim+
Green/Yellow
White/Blue:ACN
Dim-
inStallation inStructionS For diFFerent BracketS
ADJUSTABLE FITTER MOUNTING (b=AM)
1
• Separate the bracket with tool.
• Put input wire of the light across the bracket.
• Let input wire go through the bracket and lock the bracket.
2
TRUNNION MOUNTING (b=YM)
• Put the input wire of the light across the bracket.
• Fix the bracket.
3
FLOOD MOUNTING (b=FM)
• Take out the bracket; fix the bracket on the fixture.
Part # VFLL-1-LB3-CP3-MV-LVd-MM-7Pr
Certification # VFLL-1-LB3-CP3-MV-LVd-MM-7Pr
VFLL-2-LB3-CP3-MV-LVd-MM-7Pr
VFLL-2-LB3-CP3-MV-LVd-MM-7Pr
VFLL-3-LB3-CP3-MV-LVd-MM-7Pr
VFLL-3-LB3-CP3-MV-LVd-MM-7Pr
Yoke mount
bracket
Screw
Fixture
Gasket
optional BracketS and inStallation inStructionS
There are 3 optional brackets for this fixture. The following is flood light fixtures with
different brackets.
AM
YM
FM
inStallation oF led lampS
ADJUSTABLE FITTER MOUNTING (b=AM)
1
• Connect the wire correctly and put the wire into pole. Then fasten the locking
bolts between slip fitter and the pole.
• Loosen the fixing bolts and adjusting bolts, align the fixture to required angle.
Tighten adjusting bolt and fixing bolts after the angle is confirmed.
note: Adjustable angle is 0~+/-90°.
2
TRUNNION MOUNTING (b=YM)
• Drill holes on the wall as shown.
• Knock the expansion bolts into the wall.
Expansion
• Connect the fixture to the bracket and tighten the screws; connect the wires
screw
properly.
note: Adjustable angle is 0~+/-90°.
Shorting Cap
FLOOD MOUNTING (b=FM)
3
• Drill holes on the wall as shown.
• Knock the expansion bolts into the wall.
• Connect the fixture to the bracket and tighten the screws; connect the wires
properly and put them into junction box.
note: Adjustable angle is 0~+/-90°.
attention: When the photocell function is required, photocell should be
installed on the back of lamp; When it's not required, shorting cap should be
installed on the back of lamp.
inStallation 5: Function adjuStment
Open the metal plug and plastic plug counterclockwise with a screwdriver,
1
then slide the switch up and down to adjust the Wattage switch, CCT
switch or photocell On/Off.
Standard wire
L/live wire: Black\Brown;
N/null wire: White\Blue;
Ground wire: Green\Yellow-green.
warninG/aVertiSSement:
MIN 75 °C SUPPLY CONDUCTORS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
LES FILS D'ALIMENTATION 75 °C MIN
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES
INHÉRENTS.
WarninG: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or
other injuries which could be hazardous or even fatal. • Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.
notiCe: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which
the receiver is connected, and consult the dealer or an experienced radio/TV technician for help.
• Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.
Lamp
AM Bracket
Wire
Support
101
10
77
10
After adjusting the required control function, tighten the metal plug and the
2
plastic plug clockwise.
205w
150w
100w
wattage switch
Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday
1-855-eti-SSli (1-855-384-7754) www.etiSSl.com
Adjusting Bolt
Lamp
AM Bracket
Locking Bolt
Support
Wall/Pole
Lamp
Expansion Bolt
+/-90°
Expansion Bolt
Lamp
Wall/Pole
Photocell
Shorting cap
Socket
Lamp
5K
4K
3K
color temperature
switch