INSTALLATION
CHECKING FOR LEAKS
After all connections are made, check all connections and fittings on the LP gas tank valve, gas hose
and regulator for leaks with a water and soap solution.
To prevent fire or explosion while testing for a leak:
• Always perform leak test prior to lighting the heater.
• Do not smoke while testing for a leak.
• Always perform leak tests outdoors in a well-ventilated area.
• Do not use any source of flame while testing for leaks.
• Do not use the heater until any and all leaks are corrected.
• If you are unable to correct a leak, disconnect the propane supply and call a gas appliance service
dealer.
PERFORM LEAK TEST
• Prepare leak test solution by 50/50 ratio of liquid dish
soap and water. Total solution required is approximately
2 - 3 ounces (70 - 90 ml). Put leak test solution in a spray bottle.
• Ensure all control knobs are in the OFF position.
• Connect the gas hose to the gas supply.
• Open the LP gas tank valve.
• Spray leak test solution on all gas carrying connections
and fittings. Presence of bubbles at areas of applied test
solution indicates a gas leak. If leaks are detected or you
smell or hear gas, shut off the gas supply valve immediate-
ly (See Fig. 21) and repair or replace the defective part.
Do not use the heater until all leaks are corrected.
Only use the regulator and hose assembly provided! If a replacement is necessary, please call
our customer service center. Do not use replacement parts that are not intended for this heater.
Inspect the hose before each use of the heater. If it is evident there is excessive abrasion or wear,
or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement
hose assembly shall be that specified by the manufacturer.
This Heater may be Used in a Recreational Enclosure or Temporary Construction Work Enclosure
with a Remote Refillable Propane Cylinder ONLY when the Cylinder is Located Outdoors and the
Heater is Used with Hose Kit No. KR-106-01
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.
NEVER Bring a Refillable Propane Cylinder Indoors. A Fire or Explosion can Occur Causing Prop-
erty Damage, Serious Injury or Death.
CAUTION
WARNING
19
Fig. 21 - Equipment Shut-off Valve