11. Troubleshooting
Suspected malfunctions are often due to reasons which the user can rectify himself/herself. You should
check the machine therefore on the basis of this section. You can solve the problem quickly in most ca-
ses.
PROBLEM
Brewing operation fails to start
The machine does not perform
on its highest level
Water runs out of the water tank
Water runs out of the fi lter
holder
Anl_TE_CF_18_Li_SPK13.indb 20
Anl_TE_CF_18_Li_SPK13.indb 20
GB
POSSIBLE CAUSE
- The battery is not correctly
connected
- The battery is empty
- Battery performance is too low
- The battery is coming to the
end of its working life
- The water tank is empty
- The heating element is
defective
- The water tank has been
overfi lled
- Too much coff ee powder is
being used
- Too many coff ee pads have
been inserted
- The coff ee pads have been
wrongly positioned
- The coff ee powder has been
grounded too fi nely
- The coff ee powder has been
compacted too fi rmly
- 20 -
SOLUTION
- Connect correctly
- Charge the battery
- Charge the battery
- Replace the battery
- Fill the water tank
- Arrange for repair by an autho-
rized service center
- Observe the recommended
quantity of water
- Reduce the quantity of coff ee
powder
- Put in the correct amount
- Place the coff ee pad in the fi l-
ter holder as described in the
section "Brewing"
- Use a coarser degree of grin-
ding instead
- Fill in more loosely
31.07.2023 14:09:39