3. Technical Specifications
Working Voltage
Rated Current
Detection Range / Angle
Working Temperature
Dimensions
Control Unit
Sensor
Buzzer
Weight
Stage
1
2
3
4
4. Connection Diagram
• Connect the buzzer to the ALM output. There is only one way to insert the plug. Do not force.
• Connect the power cable to the PWR input. There is only one way to insert the plug. Do not force. Connect the black cable (-)
to the mass of the vehicle (usually the chassis). Connect the +12VDC red cable (+) to the reverse light.
• Connect each sensor to either one of the A, B, C or D inputs. There is only one way to insert the plug. Do not force.
APSEN1
12VDC via reversing light
12mA ~ 120mA
0.3m ~ 1.5m / H > 60°, V > 60°
-20°C ~ 70°C
85 x 45 x 25mm
Ø 25 x 21mm
60 x 42 x 16mm
279g
How To Interpret the Alarm Sounds
Distance
150 ~ 100cm
90 ~ 50cm
40 ~ 30cm
0 ~ 20cm
4
Awareness
Safe
Alarm
Alarm
Danger
Alarm Sound
bi - - - - - bi - - - - - bi
bi - - - bi - - - bi
bi - bi - bi
bi- - - - - - - - - - - - - -
PEREL

Publicidad