ENGLISH
FIG. 1
2"
(51 mm)
TRACING NON-PAIRED WIRES (FIG. 2)
1. Connect the Digital Toner-Pro's red
Connect the Digital Toner-Pro's red
respective Test Lead Inputs
2. Connect the Digital Toner-Pro's red ABN Test Clip
3. Connect the black ABN Test Clip
not in the same pair (connect to ground, if available). When tracing a shielded
not in the same pair (connect to ground, if available). When tracing a shielded
not in the same pair (connect to ground, if available). When tracing a shielded
not in the same pair (connect to ground, if available). When tracing a shielded
not in the same pair (connect to ground, if available). When tracing a shielded
cable, connect the red ABN Test Clip to the outer shield, and the black ABN
cable, connect the red ABN Test Clip to the outer shield, and the black ABN
cable, connect the red ABN Test Clip to the outer shield, and the black ABN
cable, connect the red ABN Test Clip to the outer shield, and the black ABN
Test Clip to the center conductor or ground.
Test Clip to the center conductor or ground.
4. Turn Digital Toner-Pro on by pressing the Power On/Off button
5. The Toner defaults to Digital Tone Mode, with the Digital Tone Indicator
The Toner defaults to Digital Tone Mode, with the Digital Tone Indicator
The Toner defaults to Digital Tone Mode, with the Digital Tone Indicator
, and Wire Map Indicator
T13 T13 T13
may be blinking, depending on whether the Toner is connected to a
may be blinking, depending on whether the Toner is connected to a
network port. The "CONT" Indicator
in analog mode.
in analog mode. When performing analog toning, check the "CONT"
Indicator
T4
NOTE: When performing Digital Toning, the "CONT" Indicator
not illuminate.
6. Turn on the Digital Probe-Pro (sold seperately).
7. Select the preferred tone setting using the Digital/Analog Tone Button
8. At the far end of the cable, spread the wires at least 2" (51 mm) apart, if possible.
NOTE: If performing analog toning, ensure the Digital Toner-Pro and the Digital
Probe-Pro are set to ANALOG MODE. If performing digital toning, ensure the Digital
Toner-Pro and the Digital Probe-Pro are set to DIGITAL MODE. Use the Digital Probe-
Pro (sold seperately) to scan the cable's wire pairs. Move the Digital Probe-Pro's tip
slowly across the wires. The volume will increase as it approaches the toned wire.
6
OPERATING INSTRUCTIONS
.
T20 T20 T20
When performing analog toning, check the "CONT"
When performing analog toning, check the "CONT"
When performing analog toning, check the "CONT"
. If illuminated green, you may proceed.
VDV500-223
VDV500-223
(sold seperately)
and black
T14 T14
T15 T15
to another wire in the cable, but preferably
to another wire in the cable, but preferably
T15 T15
LEDs 3 and 6 illuminated. The LEDs
LEDs 3 and 6 illuminated. The LEDs
T18 T18 T18 T18 T18
illuminates green or red only when
illuminates green or red only when
illuminates green or red only when
illuminates green or red only when
T4
ABN Test Clip leads to their
ABN Test Clip leads to their
to the wire to be traced.
to the wire to be traced.
T14 T14
.
T9
will
T4
.
T7 T7